Operation QUANTRON-A
4
74
4.10.4 Test/diagnosis
The
Test/diagnosis
menu enables function monitoring and checking of specific
sensors/actuators.
NOTICE
This menu is for information purposes only.
The list of sensors depends on the equipment of the machine.
Sub-menu
Meaning
Description
Slide test points
Test for approaching the various posi-
tion points of the sliders.
Checking the cali-
bration
Metering slide
Approaching the left and right meter-
ing slide
Voltage
Checking the operating voltage.
Level sensor
Checking the level sensors
Weigh cells
Checking the weigh cells.
M EMC
Checking the sensors for the M EMC
function.
Drop point test points Test for approaching the various posi-
tion points of the drop point.
Checking the cali-
bration
Drop point
Approaching the drop point.
Linbus
Checking the assemblies registered
via LINBUS.
TELIMAT sensor
Checking the TELIMAT sensors
Hopper cover
Checking the actuators.