4
Performing a spreading test
4.1
Conduction of a spreading test with one pass
We recommend the layout for one pass to quickly check the fertilizer distribution. More accurate
results are provided by the layout plan for two passes, see
4.2 Conduction of a spreading test with
•
Test area length 60 - 70 m
Fig. 5: Layout for one pass
Preparing the pass:
•
Select a similar fertilizer from the same fertilizing group from the fertilizing chart and set the
spreader accordingly.
•
Adjust the mounting height of the mineral fertilizer spreader according to the specifications in the
fertilizing chart.
•
Check the spreading elements (spreading discs, spreading vanes, outlet) for correct functioning
and completeness.
•
Place four collecting vessels one in front of another at a distance of 1 m in the overlap zones
(between the tracks) and two collecting vessels in the track.
Performing a spreading test with the desired travel speed and metering quantity for the
application:
•
Open the metering valves 10 m upstream of the collecting vessels.
•
Close the metering valves 30 m downstream of the collecting vessels.
•
Spread on both sides.
4. Performing a spreading test
10
5903595
PPS 5 AXIS M