Maintenance and repair
9
110
Adjustment:
The metering slide is in the position of step 2 (lightly pressed against the pin).
3.
Loosen the mounting screws on the scale of the lower scale plate.
Figure 9.14:
Scale mounting screws
4.
Adjust the scale in such a way that the
scale value 85
lies exactly under the
pointer element.
Figure 9.15:
Metering slide pointer on position 85
5.
Tighten the scale again.
6.
Repeat working steps 1 - 4 for the right metering slide.
NOTICE
Both metering slides must open
evenly
and to the same extent. Therefore, al-
ways check both metering slides.
NOTICE
After scale correction of the electronic metering slide actuators, the metering
slide test points in the ISOBUS machine control unit have to be checked as well.
Please observe the operator's manual of the ISOBUS machine control unit.
In case of deviations, please contact your dealer or an authorised specialist
workshop for adjustment.