Layout and function
9
2
2.2.5
Stop switch
By pressing the stop switch, all connected devices are set to a safe condition.
For unlocking the stop switch, turn it in the direction of the arrow until the
switch pops out again.
The stop switch is unlocked.
Figure 2.4:
Stop switch at the CCI 100
Case 1 - Spreading operation
Pressing the stop switch during spreading operation:
-
the pre-metering slides are stopped.
-
the conveyor belt is stopped.
-
the comb roller is stopped.
-
the hopper cover is stopped.
Case 2 - No spreading operation
(example: calibration/fast emptying)
If no spreading operation is active, all functions are stopped and the metering
slides remain open.
A warning message is displayed as soon as the stop switch is actuated.
1.
Rectify the cause of the fault.
2.
Unlock the stop switch
Another alarm message warning against possible unexpected move-
ments is displayed.
3.
Press the
ACK
foil key
n
CAUTION
Risk of injury from rotating spreading discs!
The spreading discs are not stopped.
Switch off the PTO shaft of the tractor.
Ensure that nobody is in the hazard zone.
!
Содержание Axent Isobus
Страница 6: ...Table of Contents IV ...
Страница 10: ...User instructions 1 4 ...
Страница 22: ...Layout and function 2 16 ...
Страница 62: ...Operation AXENT ISOBUS 4 56 ...
Страница 68: ...Loading with AXENT ISOBUS machine control unit 5 62 ...
Страница 74: ......