Содержание CAD XACT-SEND 0 0 0000 Series

Страница 1: ...DOUBLE POSITION SENSOR MANUAL AND SAFETY INSTRUCTIONS CODE XACT SEND 0XX0 X0000 ...

Страница 2: ......

Страница 3: ...nance 6 4 1 Intended use 4 2 Mounting and Installation 4 3 Maintenance and repair 4 4 Specific conditions of safe use X 5 Technical data 7 5 1 Safety ratings 5 2 Technical data 5 3 Electrical connections 5 4 Mechanical connections and spare parts 6 Tools 12 6 1 CAD Programmer 6 2 Cable for double position sensor INDEX ...

Страница 4: ...n sensor which provides an indication of the status of the pneumatically actuated valve giving the possibility to record the opening and closing positions The sensor signals the opening and closing positions through the indicating LEDs and the two transistor sensor outputs The activation position of the 2 sensor outputs can be set by following the calibration procedure 2 1 Standards and ATEX marki...

Страница 5: ...ve dust atmospheres Marking required by the harmonized standards of the Directive EN IEC 60079 0 2018 EN 60079 11 2012 EX IC Intrinsically safe protection mode Ex i EN 60079 11 2012 level c zone 2 zone 22 IIC Gas group T6 Temperature class for gas surface temperature 85 C T5 Temperature class for gas surface temperature 100 C GC EPL Equipment protection level for gas c corresponding to zone 2 IIIC...

Страница 6: ...o 80 C The ambient temperature range is specified in Certificate no IMQ 22 ATEX 021 Degree of protection EN 60529 IP65 IP67 2022 example manufacturing year Sensor model XACT SEND 0XX0 X0000 SN serial number LED PROGRAMMING NORMAL ANOMALY RED LED Blinks 2 times when valve closed position is registered Steady on in case of closed valve It flashes alternately with the GREEN LED if the valve open posi...

Страница 7: ...position press the SET button again the sensor flashes RED twice recording the closed valve position the RED LED on the programmer also flashes 5 Move the valve to the open position 6 Press the SET button again the sensor flashes GREEN twice registering the valve open position the GREEN LED on the programmer also flashes After 10 s have elapsed from the first pressing of the SET button the sensor ...

Страница 8: ...th the IEC EN 60079 17 standard Do not use a damaged or contaminated device Do not repair modify or manipulate the device In case of defects always replace the device with another original device Do not remove the marking Prevent the inside of the device from becoming contaminated when the connector is disconnected 4 4 Specific conditions of safe use X Nominal ambient temperature from 10 C to 65 C...

Страница 9: ...Maximum absorbed current without load Vin 30V 40 mA Valve opening and closing transistor outputs POS1 and POS2 Type Open collector PNP Imax 80mA Vmax 40V Operating temperature limits 10 C 80 C Storage temperature limits 10 C 80 C Degree of protection IP65 IP67 EMC compliance EN 61326 1 2006 EN61000 6 2 2006 EN61000 6 3 2007 EN 61326 2 3 2006 ...

Страница 10: ...pply Positive Power 10 30 50 2 L Power Supply Negative Power 3 SET Input Limits setting 28 4 POS1 Output Valve output closed 10 30 Vin 80 5 POS2 Output Valve output open 10 30 Vin 80 TABLE OF ABSORBED POWER WITHOUT LOAD VDC V IDC_ A P W 10 0 04 0 4 15 0 04 0 6 20 0 04 0 8 24 0 04 0 96 30 0 04 1 2 ...

Страница 11: ... without the programmer connect a N O button between the SET and Vin contacts REFERENCE FOR CONNECTOR ORIENTATION 4 2 3 5 1 1 L L SET POS1 POS2 3 4 5 2 HAZARDOUS AREA SAFE AREA VALVE POSITION SENSOR POWER SUPPLY SET N OUT1 OUT2 ISOLATED REPEATER RESISTANCES PULL DOWN ...

Страница 12: ... 57 31 8 12 5 20 40 Part code SPRING 0 60X9 1X06 Use this spring for CAD sizes A12 1 2 A19 3 4 Part code SPRING 0 60X9 1X09 Use this spring for CAD sizes A25 1 A38 1 1 2 A50 2 A63 2 1 2 A76 3 A00 4 Part code CADA0229 Use this adaptor for CAD sizes A12 1 2 A19 3 4 Part code CADA0230 Use this adaptor for CAD sizes A25 1 A38 1 1 2 A50 2 A63 2 1 2 A76 3 A00 4 ...

Страница 13: ...11 LOWER ANTIROTATION SOCKET FOR SPRING UPPER ANTIROTATION SOCKET FOR SPRING D DETAIL D DETAIL C C ATTENTION PLEASE INSERT ANTIROTATION PORTION OF BOTH SIDE OF THE SPRING INSIDE RELATED SOCKET ...

Страница 14: ...ieved just pushing 3 times the single pulsant once to start programming then for save closure point detection when actuator is on closed position and then a third time for saving the open position when the actuator is in correspondence of the open position This programming require just few seconds see section 3 1 CODE SUITABLE FOR CAD SENSOR Lenght mm inch YACT SENP 0XC0 X0000 XACT SEND 0XX0 X0000...

Страница 15: ... PLC and transmit open and close position of the actuator where sensor is installed CODE SUITABLE FOR CAD SENSOR Lenght mm inch YACT SEND 0XC0 X0000 XACT SEND 0XX0 X0000 4 00 157 YACT SEND 0XC0 X0030 XACT SEND 0XX0 X0000 30 00 1181 Ø5 CEI 20 22 PVC GREY CABLE 2 3 4 5 1 White Grey Blue Black Brown CONNECTION DIAGRAM 5 POLES FEMALE CABLE CROSS SECTION 5x0 25mm2 ...

Страница 16: ...RATTIINOX S r l Via Mara 44 I 22066 Mariano Comense CO T 39 031 3551263 info rattiinox com www rattiinox com ...