- 21 -
TIP: The ESC must be turned to “OFF” to increase engine speed to rated rpm.
If the generator is connected to multiple loads or electricity consumers, please
remember to first connect the one with the highest starting current. and last
connect the one with the lowest starting current.
5.4 Battery Charging
TIP:
Ь
The generator DC rated voltage is 12V.
Ь
Start the engine first, and then connect
the generator to the battery for charging.
Ь
Before starting to charge the battery, make
sure that the DC protector is turned on.
1. Start the engine.
2. Connect the red battery charger lead to the positive (+) battery terminal.
3. Connect the black battery charger lead to the negative (-) battery terminal.
4. Turn the ESC “off” to start battery charging.
Ь
Be sure the ESC is turned off while charging the battery.
Ь
Be sure to connect the red battery charger lead to the positive (+)battery
terminal ,and connect the black lead to the negative (-) battery terminal.
Do not reverse these positions.
Ь
Connect the battery charger leads to the battery terminals securely so that
they are not disconnected due to engine vibration or other disturbances.
Ь
Charge the battery in the correct procedure by following instructions in the
owner’s manual for the battery.
Ь
The DC protector turns off automatically if current above the rated flows
during battery charging. To restart charging the battery, turn the DC protector
Bracke
Cover
Battery