V02 en, SCC_WE
- 56 -
Error message Service 40 - 120, blink code motor
Display
Definition
Reason and remedy
Service 40
Care pump doesn`t
fill enough into
steam
generator
Care pump faulty or does not fill enough care solution into steam gene-
rator;
- After filling of the care solution into the steam generator the CDS sen-
sor sends too many pulses until the level electrode recognises water.
Check if the hose from the care pump outlet is not kinked;
- Cleanjet finishes without care phase;
- Reset error by successful completing rinse program;
Service 41
Moistening without
function
- Solenoid valve Y3 defective or moistening valve blocked; CDS does not
send any pulses;
- Reset error by successful completing rinse program;
Service 42
Care function not
possible, solenoid
Y4 defective
- Solenoid Y4 Care defective or hose to care container blocked or
kinked; CDS does not send any pulses;
- Reset error by successful completing rinse program;
Service 43
Y1, Y3 or Y4 do not
close
- CDS sensor sends always pulses; Solenoid Y1, Y3 or Y4 is passing
water
- Reset error by successful completing ABORT program;
Service 44
No steam hea-
ting during
CCare
- No temperature raise above 60°C recognised by B1 during steaming
time while being in Cleanjet phase
- Reset error by successful completing ABORT program;
Service 55
Blink code motor top see below
Service 56
Blink code motor
bottom
see below
Service 60
Initialisation of igniti-
on box incorrect
Wrong rpm informa-
tion for gas blower
Switch unit off and on again,
run SD Repair program
Service 63
Unit had done a self-
test without water;
Cool down uinit, make sure B1, B2 and B4 is below 40°C,
In basi settings - Selftest set Selftest to ON and switch unit off and on
again. Run Selftest
Service 110
SC Pumpe not
working while care
solution is inside
steam generator.
- Malfunction of SC pump during the time when Care solution was inside
the steam generator,
- Reset error by successful completing ABORT program;
Service 120
Level electrode
without signal while
care solution is
inside steam gene-
rator.
- After operating care pump M12 (filling care solution into steam gene-
rator) and topping up with water the level electrode does not recognise
water;
- Care Pump M12 or level electrode defective;
- Display only after twice starting filling solenoid Y1 yet no water is detec-
ted;
- Reset error by successful completing ABORT program;
The error messages can be seen under Diagnostic, Service history.
Blink code Motor
Reason
Remedy
1x
Starting error
contact Rational, change motor
2x, 4x, 5x, 7x, 9x, 11x,
12x
Motor defective
change motor
3x, 6x,
volatge error
check voltage supply, change motor
8x
possible starting error
check fan wheel for distortion, change motor
10x
only with 3AC motor
40.03.514
phase is missing