6 | Electrical connection
56 / 96
80.06.083_iCombiPro-iCombiClassic_IM_en-US
Color coding of the flat pins
Connection
Conductor color
Flat pin
Phase
Brown, black or gray
L1
Neutral conductor
Blue
N
Protective conductor
(Ground)
Yellow-green
PE
6.7
Closing the electrical compartment
NOTE
Trapped cable
When closing the electrical compartment, ensure that no cables or hoses
are pinched or trapped.
Device size XS GN
1. Insert the left side panel under the top frame of the housing.
2. Push the side wall upward.
3. Tighten two screws on the bottom of the side wall and one screw on the
back.
>>
The electrical compartment is closed.
Device size 6 half size GN to 10 full size GN
1. Insert the left side panel under the top frame of the housing.
2. Push the side wall upward.
3. Push the side wall inwards in the lower area.
>
The front edge is behind the plastic part and the rear sheet edge is placed
over the grounding plate.
4. Tighten two screws on the back of the device.
5. Turn the blind rivets on the front in the lower left corner and tighten.
6. Insert the grille and press it firmly.
7. Check that the floor seal is fitted correctly.
>>
The electrical compartment is closed.
Device size 20 half size GN - 20 full size GN
1. Insert the left side panel under the top frame of the housing.
2. Push the side wall upward.
3. Tighten two screws on the underside of the side wall.
>>
The electrical compartment is closed.