![Rational iCombi Pro Скачать руководство пользователя страница 5](http://html2.mh-extra.com/html/rational/icombi-pro/icombi-pro_original-installation-manual_3777017005.webp)
4 | Installation
en-US
80.51.389_iCombi Pro-iCombi Classic_IFA TG_IM_V01_US-nord
5 / 16
7
Holder drain valve
8
Drain pipe
9
Drain valve with handle
10
Connection pipe
11
Double socket
12
Silicon seal double socket
13
Pipe holder rear wall
14
Silicon seal HT pipe
15
Bracket for drain valve
16
Copper seal
17
Collection tray
18
Pipe collection tray
19
Plug for cooking cabinet, with fixing
and chain
20
Screw connection with funnel open-
ing
21
Drain fitting
4
Installation
4.1 Preparing the stand
Stand with rear wall:
Break out the perforation for the plate on
the rear wall of the stand [
Figure 02
].
Stand without rear wall [
Figure 03
]:
1. Hook the retaining plate on the rear
side of the stand on the table edge.
2. Tighten the 2 screws on the retaining
plate.
4.2 Mounting the integrated fat
drain
Mounting the drain valve and drain pipes
1. Seal the threads of the two pipe pieces
for the drain valve with teflon tape
[
Figure 04
].
2. Mount the two parts of the holder on
the drain valve with the tube angle and
the connecting pipe [
Figure 05
].
3. Turn the tube angle so that it is
mounted at a 90° angle to the holder.
4. Mount the pipe seal on the pipe socket
in the rear wall of the device
[
Figure 06
].
5. Join the pipes on the rear wall of the
device [
Figure 07
].
6. Guide the piping into the stand
[
Figure 08
].
7. Push the drain valve into the top rail of
the stand [
Figure 09
].
8. Push the piping into the pipe sleeve of
the drain valve [
Figure 10
].
9. Tighten the clamp screws on the drain
valve holder [
Figure 11
].
10. Place the front fat collection canister in
front of the stand and the rear fat col-
lection canister in the stand
[
Figure 12
]. The rear canister must
be positioned in the stand so that the
front fat collection canister can be
placed in front of it after further pre-
liminary work.
11. Insert the drain pipe in the front fat
collection canister and in the tube an-
gle [
Figure 13
].
12. Turn the drain pipe so that the pin
locks in the tube angle [
Figure 14
].
13. Push the fat collection tray into the
bottom slot of the device
[
Figure 15
].
14. Guide the piping in the cooking cabi-
net into the fat collection tray
[
Figure 16
]. Fix the plugs on the
funnel in the cooking cabinet.
Содержание iCombi Pro
Страница 2: ...2 16 80 51 389_iCombi Pro iCombi Classic_IFA TG_IM_V01_US nord en US 3 fr ca 7...
Страница 11: ...80 51 389_iCombi Pro iCombi Classic_IFA TG_IM_V01_US nord 11 16...
Страница 13: ...80 51 389_iCombi Pro iCombi Classic_IFA TG_IM_V01_US nord 13 16 1 2...
Страница 14: ...14 16 80 51 389_iCombi Pro iCombi Classic_IFA TG_IM_V01_US nord...
Страница 15: ...80 51 389_iCombi Pro iCombi Classic_IFA TG_IM_V01_US nord 15 16 1 2 1 2...