background image

19

故障檢修 / 信息

信息

關於用戶回收與丟棄舊設備及電池的信息

[非歐共體國家的處理信息]

這些符號僅有效於歐洲共同體。如果您要丟棄這些物件,請諮詢您的當地政府或 
經銷商並詢問正確的丟棄方式。

Pb

電池符號的注意事項(底部兩個符號舉例):

 

此符號可與化學符號綜合使用。在此情況下,它須符合制定給該化學的使用條件。

警告

此符號表示有關設備使用了一種輕度
易燃製冷劑。如果製冷劑洩漏並暴露
於外部的點火源,則存在燃燒風險。

此符號表示必需仔細閱讀操作說明。

此符號表示有關設備必需由服務人員
參考安裝說明來處理。

此符號表示操作說明和/或安裝說明
中内有詳細的信息。

中文

Содержание RS-YU9ZK

Страница 1: ...aller should Read the Installation Instructions then request the customer keep them for future reference Remove the remote control packed with the indoor unit If the equipment is transferred to a new...

Страница 2: ...AAA R03 3 A 1 5 12 am pm 24 2 SET ON OFF SET TIMER CANCEL OFF ON AIR SWING TEMP OFF ON SLEEP AIR CONDITIONER MODE POWERFUL FAN SPEED QUIET ON OFF TIMER CANCEL AIR SWING SLEEP AIR CONDITIONER POWERFUL...

Страница 3: ...3 4 11 12 13 14 15 16 18 19 AAA R03 2 2 Rasonic B 2 MODE DRY AUTO COOL 1 OFF ON OFF ON POWER ON 3 TEMP UP TEMP DOWN TEMP 16 0 C 30 0 C 60 F 86 F 10 C F...

Страница 4: ...4...

Страница 5: ...5 ON Ni Cd ELCB RCD ELCB BS...

Страница 6: ...6 R32 Amin m Amin m A R32 R410A R22 R32 R22 R32 R22 R32 R410A R32 R410A R32 R410A R22 R32 R410A 1 2 R32 R410A AHU a b c d...

Страница 7: ...7 e f g h i j 5 0 25 1 04 MPa 4 15 MPa 1 A Amin m 12 2 2 1 2 2 2 2 2 8 2 2...

Страница 8: ...8 2 3 2 4 CO2 2 5 2 6 2 7 2 8...

Страница 9: ...9 6 7 5 1 04 MPa 4 15 MPa 0 25 LFL 25 8 3 4 5...

Страница 10: ...10 10 a b c d e f g h 80 i j k 11 8 OFN OFN OFN OFN 9 OFN 7...

Страница 11: ...11 12...

Страница 12: ...12 ON OFF SET TIMER CANCEL OFF ON AIR SWING TEMP OFF ON MODE SLEEP AIR CONDITIONER POWERFUL FAN SPEED QUIET POWER TIMER 20 POWERFUL AIR SWING FAN SPEED AUTO FAN QUIET FAN SPEED QUIET FAN SPEED QUIET...

Страница 13: ...13 SLEEP POWERFUL FAN SPEED QUIET POWERFUL 0 5 1 2 3 4 5 6 7 8 9 OFF 0 0h ON OFF SET TIMER CANCEL 1 2 3 1 TIMER ON TIMER OFF 22 00 OFF OFF 2 3 SET ON OFF CANCEL ON OFF SET 2 SLEEP...

Страница 14: ...14 AUTO POWER COOL DRY COOL 26 0 C 28 0 C 79 F 82 F COOL DRY COOL DRY C F DBT WBT DBT WBT COOL 32 89 6 23 73 4 46 114 8 26 78 8 16 60 8 11 51 8 16 60 8 11 51 8 DBT WBT...

Страница 15: ...15 AUTO OFF ON H 99 pH 7 40 C 104 F 2 2 CZ SA31P 1 2 2 AUTO OFF ON 1 3 4...

Страница 16: ...16 POWER TIMER ON 15 TIMER ON COOL...

Страница 17: ...17 AUTO OFF ON 1 2 AUTO OFF ON AUTO 3 AUTO OFF ON 5 COOL 4 AUTO OFF ON 5 AUTO OFF ON COOL 15 COOL 8 C 14 4 F...

Страница 18: ...14 H 15 H 16 CT H 17 H 19 H 21 H 23 1 H 24 2 H 25 H 26 ION H 27 H 28 1 H 30 H 31 H 32 2 H 33 H 34 H 35 H 36 H 37 H 38 H 39 H 41 H 50 H 51 H 52 H 58 H 59 H 64 H 67 nanoe H 70 H 71 H 72 H 79 H 85 H 97...

Страница 19: ...19 Pb...

Страница 20: ...R CONDITIONER MODE POWERFUL FAN SPEED QUIET ON OFF TIMER CANCEL AIR SWING SLEEP AIR CONDITIONER POWERFUL FAN SPEED QUIET B A Inserting the batteries 3 OP EN 2 1 1 Pull out the back cover of remote con...

Страница 21: ...ion POWER When the unit is ON disappears from the remote control display 3 Press TEMP UP TEMP DOWN to select the desired temperature TEMP Up Down Selection range 16 0 C 30 0 C 60 F 86 F Press for appr...

Страница 22: ...plosive or flammable atmosphere Failure to do so could result in fire Do not insert your fingers or other objects into the air conditioner indoor or outdoor unit rotating parts may cause injury Do not...

Страница 23: ...fire Prevent electric shock by switching off the power supply and unplug Before cleaning or servicing When extended non use or During abnormally strong lightning activity CAUTION Indoor unit and outd...

Страница 24: ...eal the opening by pinching taping etc Handling of R32 is similar to R410A Operation maintenance repairing and refrigerant recovery should be carried out by trained and certified personnel in the use...

Страница 25: ...the precautions in 12 and comply with national regulations Always contact to local municipal offices for proper handling 2 Servicing 2 1 Service personnel The system is inspected regularly supervised...

Страница 26: ...ernally into the atmosphere 2 7 Checks to the refrigerating equipment Where electrical components are being changed they shall be fit for the purpose and to the correct specification At all times the...

Страница 27: ...the atmosphere from a leak 5 Cabling Check that cabling will not be subject to wear corrosion excessive pressure vibration sharp edges or any other adverse environmental effects The check shall also t...

Страница 28: ...minimize the amount of refrigerant contained in them Cylinders shall be kept in an appropriate position according to the instructions Ensure that the refrigerating system is earthed prior to charging...

Страница 29: ...employed Ensure that the correct number of cylinders for holding the total system charge are available All cylinders to be used are designated for the recovered refrigerant and labelled for that refri...

Страница 30: ...minutes Press the button again to cancel POWERFUL exit setting Upper direction Do not adjust the flap by hand For details operation refer To Learn More Lateral direction For lateral direction it is m...

Страница 31: ...n has the priority over OFF timer This operation can be cancelled by pressing the respective button until the sleep timer reaches 0 0h To set the timer ON OFF SET TIMER CANCEL 1 2 3 1 Select TIMER ON...

Страница 32: ...fixed at middle position setting Once the temperature is achieved the horizontal flap swings up down automatically In COOL DRY mode The horizontal flap swings up down automatically Auto restart contr...

Страница 33: ...maging the surface Dry the filters thoroughly under a shade away from fire or direct sunlight Replace any damaged filters Remove air filter Attach air filter Remove from the unit Insert into the unit...

Страница 34: ...n the discharged cold air may condense to water vapour Outdoor unit emits water or steam During cooling operation condensation occurs on cold pipes and the condensed water may drip from the outdoor un...

Страница 35: ...e AUTO OFF ON on the unit to select COOL mode For details refer The remote control is missing or a malfunction has occurred above After 15 minutes of operation it is normal to have the following tempe...

Страница 36: ...sensor 2 abnormality H 33 Indoor outdoor misconnection abnormality H 34 Outdoor heat sink temperature sensor abnormality H 35 Indoor outdoor water adverse current abnormality H 36 Outdoor gas pipe te...

Страница 37: ...be used in combination with a chemical symbol In this case it complies with the requirement set by the Directive for the chemical involved WARNING This symbol shows that this equipment uses a mildly f...

Страница 38: ...Memo...

Страница 39: ...Memo...

Страница 40: ...Printed in Malaysia Panasonic Corporation 1006 Oaza Kadoma Kadoma City Osaka 571 8501 Japan Website http www panasonic com Panasonic Corporation 2022 ACXF55 33890 SS1022 0...

Отзывы: