Rasonic RS-LE9SK Скачать руководство пользователя страница 13

13

English

Safety precautions

If the supply cord is damaged, it must be 

replaced by the manufacturer, service agent or 

similarly quali

fi

 ed persons in order to avoid a 

hazard.
It is strongly recommended to be installed 

with Earth Leakage Circuit Breaker (ELCB) 

or Residual Current Device (RCD) to prevent 

electric shock or 

fi

 re.

To prevent overheating, 

fi

 re or electric shock:

• Insert the power plug properly.

• Dust on the power plug should be periodically 

wiped with a dry cloth.

Stop using the product if any abnormality/failure 

occurs and disconnect the power plug or turn off 

the power switch and breaker.

(Risk of smoke/

fi

 re/electric shock) Examples of 

abnormality/failure

• The ELCB trips frequently.

• Burning smell is observed.

• Abnormal noise or vibration of the unit is 

observed.

• Water leaks from the indoor unit.

• Power cord or plug becomes abnormally hot.

• Fan speed cannot be controlled.

• The unit stops running immediately even if it is 

switched on for operation.

• The fan does not stop even if the operation is 

stopped.

Contact your local dealer immediately for 

maintenance/repair.
Replacement or installation of power plugs shall

be performed by authorised/quali

fi

 ed personnel

only. The wires in this mains lead are coloured in

accordance with the following code:

Terminals

Red

wires

live

neutral

earth

colours (GB Standard)

blue

green-yellow

brown

Black

Green/Yellow

Wiring colour may vary depending on a country

wiring code’s standard.

This equipment must be earthed to prevent 

electrical shock or 

fi

 re.

Prevent electric shock by switching off the power 

supply and unplug:

- Before cleaning or servicing,

- When extended non-use, or

- During abnormally strong lightning activity.

CAUTION

Indoor unit and outdoor unit

Do not wash the indoor unit with water, benzine, 

thinner or scouring powder to avoid damage or 

corrosion at the unit.
Do not use for preservation of precise equipment, 

food, animals, plants, artwork or other objects. 

This may cause quality deterioration, etc.
Do not use any combustible equipment in front of 

the air

fl

 ow outlet to avoid 

fi

 re propagation.

Do not expose plants or pet directly to air

fl

 ow to 

avoid injury, etc.

Do not touch the sharp aluminium 

fi

 n, 

sharp parts may cause injury.

Do not switch ON the indoor unit when waxing 

the 

fl

 oor. After waxing, aerate the room properly 

before operating the unit.
Do not install the unit in oily and smoky areas to 

prevent damage to the unit.
Do not dismantle the unit for cleaning purpose to 

avoid injury.
Do not step onto an unstable bench when 

cleaning the unit to avoid injury.
Do not place a vase or water container on the 

unit. Water may enter the unit and degrade the 

insulation. This may cause an electric shock.
Do not open window or door for long time during 

COOL/DRY mode operation.
Prevent water leakage by ensuring drainage 

pipe is:

- Connected properly,

- Kept clear of gutters and containers, or

- Not immersed in water
After a long period of use or use with any 

combustible equipment, aerate the room 

regularly.
After a long period of use, make sure the 

installation rack does not deteriorate to prevent 

the unit from falling down.

Remote control

Do not use rechargeable (Ni-Cd) batteries. It may 

damage the remote control.

To prevent malfunction or damage of the remote 

control:

• Remove the batteries if the unit is not going to 

be used for a long period of time.

• New batteries of the same type must be 

inserted following the polarity stated.

Power supply

Do not disconnect the plug by pulling the cord to 

prevent electric shock.

Содержание RS-LE9SK

Страница 1: ...ructions Air Conditioner ACXF55 01450 2 9 18 Rasonic Operating Instructions Air Conditioner 10 18 Thank you for purchasing Rasonic Air Conditioner Installation instructions attached Before operating t...

Страница 2: ...2 4 5 6 7 8 9 18 AAA R03 2 2 DBT WBT C DBT WBT DBT WBT COOL 32 23 43 26 16 11 16 11 HEAT 30 24 18 16 5 6 nanoe G...

Страница 3: ...IONER OFF ON ON OFF SET CANCEL 1 2 3 TIMER MODE TEMP CLOCK SET CHECK RESET AC RC MODE POWERFUL QUIET AIR SWING FAN SPEED nanoe G SLEEP AIR CONDITIONER ON OFF SET CANCEL 1 2 3 TIMER CLOCK SET CHECK RES...

Страница 4: ...4...

Страница 5: ...5 ELCB RCD ELCB GB ON COOL DRY Ni Cd...

Страница 6: ...NG FAN SPEED nanoe G SLEEP OFF ON ON OFF SET CANCEL 1 2 3 TIMER TEMP CLOCK CHECK 10 C F POWER TIMER nanoe G POWERFUL QUIET OFF ON AUTO COOL HEAT nanoe G nanoe G OFF ON nanoe G AUTO nanoe G POWER nanoe...

Страница 7: ...ON OFF 22 00 OFF OFF Cancel 2 2 3 SET TIMER ON OFF CANCEL ON OFF ON OFF SET ON 30 POWERFUL QUIET nanoe G SLEEP POWERFUL QUIET POWERFUL QUIET QUIET POWERFUL NORMAL POWERFUL POWERFUL QUIET 15 QUIET POWE...

Страница 8: ...ER TIMER nanoe G POWER FUL QU IET nanoe G H99 pH 7 40 C POWER TIMER nanoe G POWERFU L QUIET 1 2 2 3 POWER TIMER nanoe G POWERFU L QUIET 1 nanoe G 2 2 OFF ON COOL HEAT 15 COOL 8 C HEAT 14 C HEAT 2 3 na...

Страница 9: ...9 30 TIMER POWER ON nanoe G HEAT COOL TIMER ON OFF SET CANCEL 1 2 3 TIMER CLOCK SET CHECK RESET AC RC ON OFF SET CANCEL 1 3 TIMER CLOCK SET RESET AC RC 5 2 1 5 3 4 4...

Страница 10: ...ioner under the following temperature range DBT Dry bulb temperature WBT Wet bulb temperature Temperature C Indoor Outdoor DBT WBT DBT WBT COOL Max 32 23 43 26 Min 16 11 16 11 HEAT Max 30 24 18 Min 16...

Страница 11: ...DE POWERFUL QUIET AIR SWING FAN SPEED nanoe G SLEEP 3 2 1 8m Basic operation 1 Select the desired mode DRY AUTO HEAT COOL 2 Start stop the operation POWER Please note that the indication is on display...

Страница 12: ...ric shock or fire Confirm with authorised dealer or specialist on usage of any specified refrigerant type Using refrigerant type other than the specified may cause product damage burst and injury etc...

Страница 13: ...ly strong lightning activity CAUTION Indoor unit and outdoor unit Do not wash the indoor unit with water benzine thinner or scouring powder to avoid damage or corrosion at the unit Do not use for pres...

Страница 14: ...n may activate only once a day after the unit turned off To remove the moisture left in the internal parts the fan will operate for 30 minutes with flap opened slightly This process only applicable wh...

Страница 15: ...an be activated in all modes and can be cancelled by pressing the respective button again POWERFUL QUIET Cannot be selected at the same time POWERFUL QUIET To switch between powerful quiet QUIET POWER...

Страница 16: ...T Insert at both sides 1 nanoe G Generator Once every 2 weeks Clean with dry cotton bud Do not touch during operation Air filters Once every 2 weeks Wash rinse the filters gently with water to avoid d...

Страница 17: ...aporation occurs on pipes TIMER indicator is always on The timer setting repeats daily once set Indoor fan stops occasionally during heating operation To avoid unintended cooling effect POWER indicato...

Страница 18: ...symbols are only valid in the European Union If you wish to discard these items please contact your local authorities or dealer and ask for the correct method of disposal Pb Note for the battery symb...

Страница 19: ...19 Memo...

Страница 20: ...ACXF55 01450 SS0116 0 Printed in Malaysia Panasonic Corporation Website http www panasonic com Panasonic Corporation 2016...

Отзывы: