WIRING INSTRUCTIONS
A qualified electrician or a gas technician who is familiar with the gas appliance and gas valves that will be operated by this remote
should install the remote control system. Incorrect wiring connections
WILL
cause damage to the gas valve or electronic module
operating the gas appliance and may also damage the remote receiver.
WIRING MILLIVOLT VALVES
The remote receiver is connected to the millivolt valve using the TH (thermostat) terminals on the terminal block on the millivolt gas
valve. Connect 18 gauge solid or stranded wires from the remote receiver to the gas valve.
Operation of the remote receiver is similar to that of a thermostat in that both turn the gas valve ON
and OFF based on input signals. A thermostat’s input signals are different temperatures. The
remote receiver’s input signals come from the transmitter.
Connect each of the two wires leading from the TH terminals on the millivolt gas valve to either of
the two wire terminals on the remote receiver. Normally it does not matter which wires go to which
terminal.
WIRING ELECTRONIC SPARK IGNITIONS
The remote control receiver can be connected, in series, to a 24VAC transformer to the TR
(transformer) terminal on the ELECTRONIC MODULE. Connect the hot wire from the 24VAC
transformer to either of the wire terminals on the remote receiver. Connect another wire (not
included) between the other receiver wire terminal and the TH (thermostat) terminal on the
ELECTRONIC MODULE.
SYSTEM CHECK
MILLIVOLT VALVES
Light your gas appliance following the lighting instructions that came with the appliance. Confirm that the pilot flame is on; it must be in
operation for the main gas valve to operate.
•
Slide the 3-position button on the remote receiver to the ON position. The main gas flame (i.e., the fire) should ignite.
•
Slide the button to OFF. The flame should extinguish (the pilot flame will remain ON).
•
Slide the button to REMOTE (the center position), then press the ON button on the transmitter to change the system to ON. The
main gas flame should ignite.
ELECTRONIC IGNITION SYSTEMS
•
Slide the 3-position button on the remote receiver to the ON position. The spark electrode should begin sparking to ignite the pilot
(the pilot may ignite after only one spark). After the pilot flame is lit, the main gas valve should open and the main gas flame
should ignite.
•
Slide the button to OFF. The main gas flame and pilot flame should BOTH extinguish.
•
Slide the button to REMOTE (the center position), then press the ON button on the transmitter to change the system to ON. The
spark electrode should begin sparking to ignite the pilot. After the pilot is lit, the main gas valve should open and the main gas
flame should ignite.
GENERAL INFORMATION
LEARNING TRANSMITTER TO RECEIVER
Each transmitter uses a unique security code. It will be necessary to press the LEARN button on the receiver to accept the transmitter
security code upon initial use, if batteries are replaced, or if a replacement transmitter is purchased from your dealer or the factory. In
order for the receiver to accept the transmitter security code, be sure the slide button on the receiver is in the REMOTE position; the
receiver will
not
LEARN if the slide switch is in the ON or OFF position. The LEARN button in located on the front face of the receiver;
inside the small hole labeled LEARN. Using a small screwdriver or end of a paperclip gently press and release the black LEARN button
inside the hole. When you release the LEARN button the receiver will emit an audible “beep”. After the receiver emits the beep press
the transmitter ANY button and release. The receiver will emit several beeps indicating that the transmitter’s code has been accepted