Rasmussen F Скачать руководство пользователя страница 4

STEP TWO: Burner Pan Assembly (continued).

Accessory Match Lighted Manual V-17 Valve
• (For use only with Natural Gas Models F, FH, FX, FXH)

WARNING: A SAFETY PILOT MUST BE INSTALLED ON ALL UNITS

DESIGNED OR CONVERTED TO BURN PROPANE/LP GAS

1. Apply pipe compound to threaded end of  3 / 8 "   B U R N E R   P L U G   ( A ) .   At opposite end from gas supply, thread  BURNER
PLUG (A)
 into BURNER PIPE (B) and wrench tighten.

2. Wrench tighten LOCKING PAL NUT (C) onto 3/8" STREET EL (D).

3. Apply pipe compound to threaded end of 3/8" STREET EL (D). Thread into BURNER TUBE (B) and wrench tighten
 to position shown.

4. Thread  O R I F I C E   S P U D   ( E )   into  3 / 8 "   V A L V E   ( F )  and
wrench tighten.

5. Apply pipe compound to  orifice end of  3 / 8 "   V - 1 7   V A L V E
( F ) 
. Thread into 3 / 8 "   S T R E E T   E L   ( D )  and wrench tighten to
position shown.

6. Apply pipe compound to inlet side threads of  V - 1 7   V A L V E
( F ) 
.Thread 3/8" CONNECTOR FITTING (G) onto inlet side
of V-17 VALVE (F) and wrench tighten.
7. Insert the  RATING PLATE-HEAT SHIELD (H) between

H

F

G

I

LOCKING  PAL  NUT
( C ) 
 

and 

BURNER

TUBE 

( B ) 

Wrench

tighten  the  LOCKING
PAL NUT
.

8. Insert 

KEY 

( I )

sleeve 

 

over 

V - 1 7

V A L V E   ( F )  stem. Insert
screw and tighten.

A

B

C

D

E

   FIGURE 5

Accessory Safety Pilot Lighting Kit SPK3:
• SPK3-F (For use with Natural Gas Models F, FH, FX, FXH)
• SPK-3-FA (For use with Propane Gas Models FA, FAH, FAX, FAXH).

1.  Verify assembly of Safety Pilot in accordance with the SPK3-F/FA SAFETY PILOT INSTRUCTION SHEET.
2.  Apply pipe compound to BURNER PLUG. Insert and wrench tighten into BURNER TUBE opposite gas supply side.  Apply pipe

compound to outside threads of the valve side of the  BURNER TUBE and insert assembled SPK3 VALVE onto threads.  
Using wrench placed on SPK3 VALVE at the WRENCH ATTACH POINT, tighten to position shown below.

3.  Align the PILOT-THERMOCOUPLE ASSEMBLY over BURNER PAN.  Using NUT and BOLT through pre-punched hole in

back of burner pan, attach and ensure that the  P I L O T  BURNER is over the BURNER TUBE CENTER LINE.

ATTENTION:  THERMOCOUPLE LEAD and PILOT TUBING should be coiled behind SPK3 VALVE.

4.  With the notched end over the SPK3 VALVE OUTLET FITTING, place the HEAT SHIELD over the SPK3 VALVE.

WARNING:  HEAT SHIELD MUST BE INSTALLED TO PREVENT PREMATURE

VALVE FAILURE AND/OR VOIDING OF VALVE MANUFACTURER'S WARRANTY

ON      OFF

FROM PILOT POSITION
      SLIGHT PUSH TO
            TURN OFF
      FULL PUSH TO
                 LIGHT

BURNER PLUG

BURNER TUBE

VALVE ASSEMBLY

PILOT-THERMOCOUPLE ASSEMBLY

THERMOCOUPLE LEAD AND PILOT TUBING

HEAT SHIELD

VALVE OUTLET FITTING

BOLT

NUT

SPK3-FA  AIR MIXER (FOR USE 

WITH PROPANE/LP  GAS

FIGURE 6

WRENCH ATTACH POINT

.

  4

Содержание F

Страница 1: ...gas suppliers instructions If you cannot reach your gas supplier call the fire department IMPORTANT INFORMATION THIS GAS LOG SET MUST BE INSTALLED IN A FULLY VENTED SOLID FUEL BURNING FIREPLACE WITH...

Страница 2: ...the Burner WARNING CARBON MONOXIDE POISONING MAY LEAD TO DEATH When used without fresh air gas log set may give off carbon monoxide an odorless colorless poisonous gas Some people pregnant women pers...

Страница 3: ...possible Center GRATE left to right 2 With open edge facing out place BURNER PAN beneath grate with leading edge approximately one inch forward of GRATE front legs 3 Mark positions of GRATE and BURNE...

Страница 4: ...g Kit SPK3 SPK3 F For use with Natural Gas Models F FH FX FXH SPK 3 FA For use with Propane Gas Models FA FAH FAX FAXH 1 Verify assembly of Safety Pilot in accordance with the SPK3 F FA SAFETY PILOT I...

Страница 5: ...y bending ALUMINUM CONNECTOR TUBE C align and connect without pipe compound to the FLARED BURNER INPUT FITTING D Wrench tighten NOTE ALUMINUM CONNECTOR TUBE C may kink or break causing air flow noise...

Страница 6: ...FX FXH 1 Ensure that MANUAL V 17 VALVE is completely closed See FIGURE 5 2 Open FIREPLACE GAS SUPPLY VALVE See FIGURE 7 3 Place lighted match on embers near inlet end of burner DO NOT HOLD MATCH IN HA...

Страница 7: ...erence between hot tip and cold junction base Check that thermocouple assembly is installed on side of burner on bracket per instructions Check that only tip of thermocouple is in main burner flame Re...

Страница 8: ...damages of any kind whether based upon warranty contract or negligence arising in connection with the sale use or repair of the product Some states do not allow the exclusion or limitation of inciden...

Отзывы: