Chapter 8: Nodes, Node Groups, and Interfaces
106
If the IT device has not been added to Power IQ yet, accept the
default value for the external key or change it, but make sure to
use the same value when adding the IT device to Power IQ. You
can quickly make a file of all node and interface information by
exporting. See
Export Nodes
(on page 123).
2. Select the Power IQ that manages the IT device in the Managing
Device field. You must add information about this Power IQ to CC-
SG before it appears in this field. See
Configuring Power IQ
Services
(on page 305).
3. Type a description of this interface in the Description field.
4. Click OK to save your changes.
Web Browser Interface
You can add a Web Browser Interface to create a connection to a device
with an embedded web server, such as a Dominion PX. See
Example:
Adding a Web Browser Interface to a PX Node
(on page 108). For a
blade chassis with an integrated KVM switch, if you have assigned a
URL or IP address to it on the KX2 device, a Web Browser interface is
automatically added.
A Web Browser interface can also be used to connect to any web
application, such as the web application associated with an RSA, DRAC
or ILO Processor card.
A Web Browser Interface may not allow automatic login if the web
application requires information other than username and password,
such as a session ID.
Users must have the Node In-Band Access privilege to access a Web
Browser Interface.
You must have DNS configured or URLs will not resolve. You do not
need to have DNS configured for IP addresses.
To add a web browser interface:
1. The default name for a Web Browser Interface is Web Browser. You
can change the name in the Name field. See
Naming Conventions
(on page 353) for details on CC-SG's rules for name lengths.
2. Type a TCP Port for this connection in the TCP Port field. If you are
using HTTPS in the URL, you must set the TCP port to 443.
Optional.
3. Type the URL or domain name for the web application in the URL
field. Note that you must enter the URL at which the web application
expects to read the username and password. Maximum is 120
characters. Follow these examples for correct formats:
http(s)://192.168.1.1/login.asp
Содержание Home Security System
Страница 18: ......
Страница 26: ...Chapter 2 Accessing CC SG 8 CC SG Admin Client Upon valid login the CC SG Admin Client appears...
Страница 320: ...Chapter 16 Diagnostic Console 302 NTP is not enabled or not configured properly NTP is properly configured and running...
Страница 369: ...Appendix I FAQs 351...
Страница 383: ......