5
Units
Voltage
Circuit Breaker/
Fuse sizes(AMPS)
Macerator amps @
nominal voltage
10
Feet
20
Feet
30
Feet
40
Feet
50
Feet
12V
25
16
12AWG 10AWG 8AWG
6AWG 6AWG
24V
15
8
14AWG 10AWG 10AWG 8AWG 6AWG
SPECIFICA
TIONS
HEAD VS FLOW RATES
Head
Flow
Max DC Amps
Ft [m] gpm[lpm] 12V 24V
0 [0]
11[42]
10.9 5,4
5 [1.5]
10.1[38]
11.1 5.6
10 [3]
9[34]
11.4 5.8
15 [4.6]
7.7[29]
11.8 5.9
20 [6.1]
6.4 [24]
12.3 6.2
Maximum Operating Head = 30 feet
Lift: 4 ft [1.2 m] Dry
5 ft [1.5 M] Wet
PUMP:
Self priming Flexible rubber
impeller with Stainless steel
wear plate
Impeller:
Raritan Nitrile compound with
wax
Blade:
Stainless steel double cut
Seal:
Viton Lip with 316 SS spring
and case
Motor:
Permanent magnet type, fully
enclosed, stainless steel shaft,
thermal protection for overload,
Powder coated housing with
sealed ball bearing
Ports:
Model 53100**:
Inlet: 1-1/2” hose barb &
1-1/2” MNPT Male
Model 53101**:
Inlet: 1-1/2" FNPT
Both Models:
Outlet: 3/4” MNPT and 1" hose
barb
Lead wires:
14 GA, Red and black
Fuse:
See wire size chart
Duty Cycle:
Intermittent duty only
Dimensions:
See page 1
Weight:
5 lbs.
Approvals:
Ignition protected, ISO 8846,
CE compliant available
Product Specifications
Recommended Wire and Breaker size for Macerator pump
Notes:
1. Distances are from source to the unit and back to source.
2. Recommended conductor wire minimum AWG for 3% voltage drop.
3. Recommended conductor sizes are based on 105
0
C rated insulation. Refer to ABYC standards for
other insulation ratings.
L552 1022jlc
CONVERSIONS
Wire - AWG to mm
2
Feet to Meters
AWG
16
14
12
10
8
6
4
2
mm
2
1.5 2.5 4.0 6.0 10.0 16.0 25.0 35.0
Ft
10
15
20
25
30
40
50
M
3.1 4.6 6.1 7.6
9.2
12.2 15.2
5
** Specify Voltage 12 (12 VDC) or 24 (24 VDC)