background image

1

  THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND 
  FOLLOWED DURING BOTH INSTALLATION AND OPERATION

 

 WARNING:

 

Raritan Engineering Company, Inc. Recommends that a qualified  person or electrician install this 

product.  Equipment damage, injury to personnel or death could result from improper installation.  

Raritan Engineering Company,  Inc.  accepts no responsibility or liability for  damage to equip-

ment, or injury or death to personnel,  that may result from improper installation or operation of 

this product.

  WARNING:

 

RISK OF SHOCK OR FIRE 

- If the pump is operated in an area containing flammable vapors, the 

wire leads must be joined by insulated mechanical locking connectors. Loose or inadequate wire 

connections can spark, resulting in an explosion resulting in property damage, injury, or death.  

Always use recommended fuse/circuit breaker and wire size.

  WARNING:

 

Hazard of Flooding 

- Any installation made below the waterline must have vented loops posi

-

tioned properly and all hose connections should be double-clamped.  Both intake and discharge 

seacocks should always be in the closed position when the toilet is not in use.  Failure to do so 

may result in flooding, property damage and loss of life.

Model 53 Macerator Pump

Installation, Operation and Repair Manual

1-856-825-4900

www.raritaneng.com

4 3/9
a111b

1 a25b Nr��

1 1/2" PT[]

F 3/4
a249b

2

a51b

5 8/16

a138b

3 F/16

aF0b

1 13/16

a45b

1/2

a13b

1 3/4

a44b

11/16

a18b

3 5/9

aF1b

51

2

a13Fb

6 3

16

a158b

Macerator Pump 53100**

 

Macerator pump with Waste Valve 53101**

L552  1022jlc                                                                                 

4 3/4
a120b

1 a25b Nr��

1 1/2" PT[]

1 1/2 a39b Nr��

5 3/4
a145b

2

a51b

10 1/9

a258b

3 5/9

aM1b

5 3/4
a146b

1 13/16

a45b

3 M/16

aM0b

1/2

a13b

1 3/4

a44b

11/16

a18b

3 13/16

aM8b

    1

** Specify Voltage 12 (12 VDC) or 24 (24 VDC)

Inches [MM]

Inches [MM]

Содержание 53

Страница 1: ...age injury or death Always use recommended fuse circuit breaker and wire size WARNING Hazard of Flooding Any installation made below the waterline must have vented loops posi tioned properly and all h...

Страница 2: ...lly After periods of non use impeller can stick To loosen open rear shaft cover and turn motor shaft clockwise with a flat tip screwdriver Then replace shaft cover For extended periods of non use pump...

Страница 3: ...RNING Any air leak on inlet side can cause pump to run dry and can damage impeller and impeller housing Check all inlet side con nections even those on deck plates All runs should be smooth with no ki...

Страница 4: ...sound when tank is empty If mounting in area where ignition protection is required use only ignition protected switch 4 Wire as per Fig 5 Wiring with Optional Smart Macerator Control FIG 6 NOTE Switc...

Страница 5: ...ion for overload Powder coated housing with sealed ball bearing Ports Model 53100 Inlet 1 1 2 hose barb 1 1 2 MNPT Male Model 53101 Inlet 1 1 2 FNPT Both Models Outlet 3 4 MNPT and 1 hose barb Lead wi...

Страница 6: ...using 18 F144 10 18 8 SS Flat Washer No Part Description 19 53155 Teeth Housing 20 53165 Pump Adapter 21 25103 Pump Adapter O Ring 22 F326 1 4 20 x 1 3 4 Hex CAP Head Screws 23 1226B 1 4 SS Nut 24 531...

Страница 7: ...53100 Disconnect inlet hose All models Shutoff discharge valve if installed Remove clip 13 and remove fitting 10 11 Pump can be unbolted and removed for disassembly to a convenient location Remove 4...

Страница 8: ...ARISE BY IMPLICATION OR OPERATION OF LAW IS HEREBY EXCLUDED AND DISCLAIMED ALL IMPLIED WARRANTIES SUCH ASTHOSE OF MERCHANTABILITYAND OF FITNESS FORAPARTICULAR PURPOSE IFAPPLICABLE ASWELLASANYIMPLIED W...

Отзывы: