WIRING

3

Fig. 2    WIRING FOR MULTIFUNCTION MOMENTARY CONTROL,  

FRESHWATER MODEL

WIRING

    WARNING:  Hazard of Shock and Fire

•  Always use proper wire, wire connectors 

and fuse/circuit breaker.  See Specification 

Chart.

•  Secure wire properly.

•  Do not connect appliances to toilet circuit.

•  Make sure power is off before proceeding.

•  Use  proper  wire  terminals  for  all  wire 

connections.

1. 

Determine proper wire size by measuring 

distance from:

  •  Power Source to push button to toilet 

motor and back to power source.

  •  Remote  pump  units  -  also  include 

distance from power source for remote 

pump to remote pump and back.  Same 

wire gauge must be used for both 

discharge  and remote pump.

To start Electroscan from  toilet control, run  

a wire from “to MSD “ to terminal marked    

“EXT TRIG” inside Electroscan control mod

-

ule (black box).

To start toilet equipped with Smart  toilet 

control from Electroscan, connect “Head1” to 

“FROM MSD “.  

For Lectra/San MC, EC call Raritan Customer 

Service

MSD OPERATION

2.  Select proper wire and fuse/circuit breaker 

size from Specifications on specification 

page.

3.  Install fuse/circuit breaker in positive line 

at source.

4.  Wire control to the toilet and battery using 

one of the following wiring diagrams.

FLUSH

EMPTY

FILL

DISCHARGE 

PUMP

BLACK

(12AWG)

RED

(12AWG)

SEE 

RECOMMENDED 

WIRE SIZE

BLACK

(16AWG)

FUSE/

CIRCUIT BREAKER

BATTERY

BLUE

(16AWG)

SEE 

RECOMMENDED 

WIRE SIZE

WATER 

VALVE

FILL/EMPTY SWITCH

WIRE

JUMPER

GRAY

CABLE

FILL

WHITE

EMPTY

BLACK

IN+

RED

IN

 PU

M

P / VAL

VE -

IN

 PU

M

P / VAL

VE +

BATT +

DI

S

CH -

DI

S

CH +

TO M

SD

BATT -

SF IN

 VAL

VE -

SF IN

 VAL

VE +

SEA/FR

ESH

SWITC

H

FIL

L

/EM

PTY

SWITC

H

R

W

B

W

B

R

221551

2 1

4

3

L483  0216jlc                                              

Отзывы: