background image

8

530 Orange Street, Millville, NJ  08332 USA
Telephone:   856-825-4900

   FAX:   856-825-4409

www.raritaneng.com

Southern Office and Plant

:

3101 SW Second Avenue, Fort Lauderdale, FL 33315 USA
Telephone:   954-525-0378

   FAX:   954-764-4370

     Specifications subject to change without notice.               Printed in USA

L206  0911kgs

LIMITED WARRANTY

Raritan Engineering Company warrants to the original purchaser that this product is free of defects in
materials or workmanship from the product’s date of purchase and should this product prove defective by
reason of improper workmanship and/or materials, Raritan shall, at its sole option, repair or replace the
product.  For a period of five years from the date of purchase, Raritan warrants the inner tank against leaks
provided the anode in the hot water outlet is checked annually.  Raritan warrants all other parts for a two year
period.
     1.  TO OBTAIN WARRANTY SERVICE, Consumer must deliver the product prepaid, together with
a detailed description of the problem, to Raritan at 530 Orange St., Millville, N.J. 08332, or 3101 SW 2nd
Ave. Ft. Lauderdale, FL 33315.  When requesting warranty service, purchaser must present a sales slip or
other document which establishes proof of purchase. THE RETURN OF THE OWNER REGISTRATION
CARD IS NOT A CONDITION PRECEDENT OF WARRANTY COVERAGE.  However, please
complete and return the owner Registration Card so that Raritan can contact you should a question of safety
arise which could affect you.
     2.  THIS WARRANTY DOES NOT COVER defects caused by modifications, alterations, repairs or
service of this product by anyone other than Raritan; defects in materials or workmanship supplied by others
in the process of installation of this product; defects caused by installation of this product other than in
accordance with the manufacturer’s recommended installation instructions or standard industry procedures;
physical abuse to, or misuse of, this product.  This warranty also does not cover damages to equipment caused
by fire, flood, external water, excessive corrosion or Act of God.
     3.  ANY EXPRESS WARRANTY NOT PROVIDED HEREIN, AND ANY REMEDY FOR BREACH
OF CONTRACT WHICH BUT FOR THIS PROVISION MIGHT ARISE BY IMPLICATION OR
OPERATION OF LAW, IS HEREBY EXCLUDED AND DISCLAIMED.  ALL IMPLIED WARRAN-
TIES SUCH AS THOSE OF MERCHANTABILITY AND OF FITNESS FOR A PARTICULAR
PURPOSE, IF APPLICABLE, AS WELL AS ANY IMPLIED WARRANTIES WHICH MIGHT ARISE
BY IMPLICATION OF LAW, ARE EXPRESSLY LIMITED TO A TERM OF  TWO YEARS.  SOME
STATES DO NOT ALLOW LIMITATIONS ON HOW LONG A LIMITED WARRANTY LASTS, SO
THE ABOVE LIMITATION MAY NOT APPLY TO YOU.
     4.  UNDER NO CIRCUMSTANCES SHALL RARITAN BE LIABLE TO PURCHASER OR ANY
OTHER PERSONS FOR ANY SPECIAL OR CONSEQUENTIAL DAMAGES, WHETHER ARISING
OUT OF BREACH OF WARRANTY,  BREACH OF CONTRACT, OR OTHERWISE.  SOME STATES
DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL
DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU.
     5.  No other person or entity is authorized to make any express warranty, promise or affirmation of fact
or to assume any other liability on behalf of Raritan in connection with its products except as specifically
set forth in this warranty.
     6.  This warranty gives you specific legal rights, and you may also have other rights which vary from state
to state.

8

Содержание 1700 Series

Страница 1: ...ater to grounded AC system 3 Install or locate water heater only in accordance with the provided installation instructions 4 Use water heater only for its intended use as described in this manual 5 Donotuseanextensioncord Contactaqualified electrician to have wiring properly installed 6 Supervise children when using hot water Temperaturelimitingvalvesarerecommended at the point of use such as show...

Страница 2: ...ckwireson lower side of thermostat to studs of the element 9 Reinstall personal protector panel NOTE Check for leaks before proceeding 10 Replace access panel 11 Turn on AC power Replacing The Heating Element WARNING Danger of shock Be sure to turn power off 1 Turn off water pressure pump and open all hot water faucets When water has stopped flowing pressure in water heater has been relieved 2 Dra...

Страница 3: ...d Pipewrench screwdriver nutdriver and wrench es for mounting bolts or lag bolts MOUNTING THE HEATER 1 Selectanareawheretheheaterwillnotbesubjected to water spray especially salt water NOTE Accessorhatchmustbelargeenough for future servicing and or replacement 2 Position heater so that electrical cover plates plumbing nipples and heat exchanger fittings are easily accessible 3 Usingthefourmounting...

Страница 4: ...water heater 2 Use ONLY STRANDED 12 3 10 3 for model 17120203 and 17200203 cable to the heater NEVER use solid ROMEX type wire on a boat vessel vibration causes breakage due to metal fatigue see U S Coast Guard CFR Title 33 Part 183 423 3 Secure wire at intervals of 18 45 7cm Allow about24 61cm ofextrawiretomakenecessary connections White Black Service Line HOT Black Thermostat Wire w crimp Connec...

Страница 5: ...r power attheheatingelement Ifpowerisavailableatheating element heating element is burned out If power is not available at heating element replace thermostat B1 Checkthermostatoperationandreplaceitifbad See visualaidreferenceatwww raritaneng com techsup port repair shop Use qualified electrician if you cannot determine whether or not thermostat is opera tional B2 If heater is equipped with a heat ...

Страница 6: ... 9cm marine plywood All parts are screwed together PART NUMBERS WH1A S Heating Element 120V screw in with gasket WH1B S Heating Element 240V screw in with gasket WH1D S Heating Element 4500 watt 240V screw in with Gasket WH1GS Heating Element Gasket WH3 Temperature and Pressure Relief Valve WH16 Thermostat 1790610 Anode 6 gallon 1790010 Anode 12 and 20 gallon Parts may be ordered at www raritaneng...

Страница 7: ...The valve should then be reopened enough to establish the proper engine operating temperature Engine temperature should be monitored to verify that the entirecoolingsystemisfunctioningproperly Open valve 4 if heated water temperature exceeds 120 F 49 C WARNING Pipingandgatevalve Item 4 may become extremely hot while engine is operating Be sure to wear heavy gloves when adjusting gate valve SPECIFI...

Страница 8: ... or service of this product by anyone other than Raritan defects in materials or workmanship supplied by others in the process of installation of this product defects caused by installation of this product other than in accordancewiththemanufacturer srecommendedinstallationinstructionsorstandardindustryprocedures physicalabuseto ormisuseof thisproduct Thiswarrantyalsodoesnotcoverdamagestoequipment...

Отзывы: