Technical

Range

Resolution

Accuracy

-50°C~+1000°C 1°C

±3% of rdg ± 5 dgts

-58°F~+1832°F

1°F

±3% of rdg ± 8 dgts

Temperature.

Sensor: Type K Thermocouple.

Overload protection: 250V DC or AC rms.

Audible continuity.

Audible threshold: Less than 100Ω.

Test current: <0.3mA.

Overload protection: 250V DC or AC rms.

Temperature Measuring 

Range

-40°C ~ 200°C

-40°F ~ 392°F

Accuracy Range

± 1.5°C

Response Time

0.5 Seconds

Compliance

BS EN60584-1

BS EN60584-3

Technical

Thermocouple

Содержание R00190

Страница 1: ...R00190 Before using the instrument please read this manual carefully and save for future reference R00193 DIGITAL MULTIMETER With Temperature Function USER MANUAL...

Страница 2: ...meter WARNING symbol indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION symbol indicates a potentially hazardous situation which if not av...

Страница 3: ...ted to particularly hazardous voltages For maximum safety the meter and its test leads should not be handled when these terminals are energized Input limits Function Maximum input V DC or V AC CATIII...

Страница 4: ...detergents Always remove any test temperature leads when not in use Calibration To maintain the integrity of measurements Wolseley recommends that the multimeter is calibrated annually at an approved...

Страница 5: ...couple adaptor Symbols BAT HOLD MAX AUTO AC DC F C m Continuity Low Battery Diode Data Hold Max data Hold Auto ranging Alternating Current or Voltage Direct Current or Voltage Degrees Fahrenheit Degre...

Страница 6: ...5 Physical Appearance Features Height 140mm Width 66mm Depth 37mm Weight 208g without battery...

Страница 7: ...hat automatically shuts the meter off if 15 minutes elapse between uses 2 If OL appears in the display during a measurement the value exceeds the range you have selected Change to a higher range NOTE...

Страница 8: ...ents being made and is generally the best mode for most measurements For measurement situations requiring that a range be manually selected perform the following 1 Press the RANGE button The AUTO disp...

Страница 9: ...display 2 Press the Data Hold Back light control button to return to normal operation 3 Press and hold the Data Hold Back light control button for 2 seconds to turn the back light on Pressing and hol...

Страница 10: ...d banana plug into the positive V jack 3 Touch the test probe tips to the circuit under test Be sure to observe the correct polarity red lead to positive black lead to negative 4 Read the voltage in t...

Страница 11: ...t is being switched ON or OFF Large voltage surges may occur that can damage the meter 1 Set the function switch to the V AC position V will appear in the display 2 Insert the black test lead banana p...

Страница 12: ...nts up to 2000 A DC set the function switch to the A position and insert the red test lead banana plug into the A jack 3 For current measurements up to 200mA DC set the function switch to the mA range...

Страница 13: ...rcuit 8 Apply power to the circuit 9 Read the current in the display The display will indicate the proper decimal point value and symbol AC Current Measurements WARNING To avoid electric shock do not...

Страница 14: ...anana plug into the mA jack 4 For current measurements up to 10A AC set the function switch to the A position and insert the red test lead banana plug into the 10A jack 5 Press the mode button until A...

Страница 15: ...atteries and unplug the line cords 1 Set the function switch to the position 2 Insert the black test lead banana plug into the negative COM jack and the red test lead banana plug into the positive jac...

Страница 16: ...ve jack 3 Press the mode button until the symbol appears in the display 4 Touch the test probe tips to the circuit or wire you wish to check 5 If the resistance is less than approximately 30 the audib...

Страница 17: ...osition Note this reading 6 The diode or junction can be evaluated as follows A If one reading shows a value and the other reading shows OL the diode is good B If both readings show OL the device is o...

Страница 18: ...ton will change temperature unit between C F 3 Touch the temperature probe head to the part whose temperature you wish to measure Keep the probe touching the part under test until the reading stabiliz...

Страница 19: ...t hand side of the LCD display The battery should be replaced 2 Follow instructions for installing battery see the Battery Installation section of this manual 3 Dispose of the old battery properly WAR...

Страница 20: ...d screwdriver 3 Insert the battery into battery holder observing the correct polarity 4 Put the battery door back in place Secure with the two screws NOTE If your meter does not work properly check th...

Страница 21: ...crew on the battery door using a Phillips head screwdriver 3 Remove the old fuse from its holder by gently pulling it out 3 Install the new fuse into the holder 4 Always use a fuse of the proper size...

Страница 22: ...Low Battery Indication BAT is displayed when battery voltage drops below the operating level Measurement Rate 2 times per second nominal Auto Power Off Approx 15mins of inactivity Operating Environmen...

Страница 23: ...nge Resolution Accuracy 200 0m V 0 1m V 0 5 of rdg 2 dgts 2 000 V 1m V 1 0 of rdg 2 dgts 20 00 V 10m V 200 0 V 100m V 600 V 1 V 1 2 of rdg 2 dgts DC Voltage auto ranging Input Impedance 10M Maximum In...

Страница 24: ...3 dgts 20 00 V 10m V 1 5 of rdg 3 dgts 200 0 V 100m V 600 V 1 V 2 0 of rdg 4 dgts Input Impedance 10M Frequency range 50 to 60Hz Maximum Input 600V DC rms Range Resolution Accuracy 200 0uA 0 1uA 1 0...

Страница 25: ...ge Range Resolution Accuracy 200 0uA 0 1uA 1 5 of rdg 5 dgts 2000uA 1uA 1 8 of rdg 5 dgts 20 00mA 10uA 200 0mA 100uA 10A 10mA 3 0 of rdg 7 dgts AC Current auto ranging for uA and mA Overload protectio...

Страница 26: ...dgts 2 000K 1 1 0 of rdg 2 dgts 20 00K 10 1 2 of rdg 2 dgts 200 0K 100 2 000M 1K 20 00M 10K 2 0 of rdg 3 dgts Input protection 250V Test current Resolution Accuracy 0 3mA typical 1mV 10 of rdg 5 dgts...

Страница 27: ...Type K Thermocouple Overload protection 250V DC or AC rms Audible continuity Audible threshold Less than 100 Test current 0 3mA Overload protection 250V DC or AC rms Temperature Measuring Range 40 C 2...

Страница 28: ...ip This warranty does not cover fuses disposable batteries or damage from accident neglect misuse alteration contamination or abnormal conditions of operation or handling WEEE Directive 2012 19 EU At...

Отзывы: