background image

 

plate.

 

ATTENTION!

 

The motors are not of an anti-explosive type ! Do not install them where inflamable vapours 

 

can be present !

5.4 

Connecting

 

- Before connection, make shure that the tubing and the suction tank are  free of dirt and 

 

thread residue that could damage the pump and ist accessories.

 

- Only use suitable tubings, flow meter and nozzles and also adequate clamps (not included 

 

in deliivery!).

 

- Do not use conical threaded joints that could damage the threaded pump openings if 

 

excessively tightened.

 

Step 1: Suction hose :

 

- Connect the suction hose to the hose tail (3) at the inlet of the pump (1).

 

Step 2: Delivery hose:

 

- Connect the delivery hose to the hose tail (3) outlet of the pump (1) or the flow meter.

 

Step 3: Flow meter (optional):

 

- Connect the flow meter by the elbow to the outlet of the pump.

 

Step 4: Nozzle (optional):

 

- Connect the dispensing nozzle by the clamp to the delivery hose.

5.5. Dispensing
 

 After installation the completed pump system as picture indicated, connect the power 

 

supply and start dispensing.

 

ATTENTION ! 

 

It is the installer‘s repsonsibility to use tubing with adequate characteristics.Loosening of the 

 

Connections (thereded connections, flanging, gasket seals) can cause serious ecological 

 

and safety problem.

 

Check all the connections after the initial installation and on a daily basis after that.  Tighten 

 

the connections, if necessary.

6. Spare parts and accessories

3

4

5

6

7

2

1

8

Pos

.

Beschreibung Menge

1

Zapfpistole

1

2

Schelle

3

3

Füllschlauch

1

4

Schlauchnippel

2

5

O-Ring

2

6

Pumpe

1

7

Überwurfmutter

2

8

Saugschlauch

1

4

+49 (6158) 92980-0

Содержание ABP 35 G12

Страница 1: ...of equipment are checked carefully before delivery for their perfect composition and function In case of improper use all rights to claim under guarantee are void i Weiterentwicklung im Sinne des For...

Страница 2: ...ed Always wear safety cloths respecting the applicable regulations for accident prevention Only use this device conforming to its purpose and function Improper use can cause severe injuries Caution mo...

Страница 3: ...s not being in any way dangerous or polluting Refer to local regulations for ist disposal 5 2 Electrical power suply 5 2 1 During installation and maintenance make shure that the electric supply lines...

Страница 4: ...1 or the flow meter Step 3 Flow meter optional Connect the flow meter by the elbow to the outlet of the pump Step 4 Nozzle optional Connect the dispensing nozzle by the clamp to the delivery hose 5 5...

Страница 5: ...nstructed to require a minimum of maintenance In any case always bear in mind the following basic recommendations for a good functioning of the pump On a weekly basis check that the tubing joints have...

Страница 6: ...e user 10 Warranty 10 1 In case of insufficient maintenance faults on operation use of not adequate spare parts or attachments all liabilities and rights of claim under guarantee are void 10 2 The man...

Страница 7: ...7 49 6158 92980 0...

Страница 8: ...Fax 49 6158 92980 50 info rapid group de Rapid Group GmbH Bahnhofstra e 53 55 64560 Riedstadt Telefon 49 6158 92980 0 www rapid group de 8 49 6158 92980 0...

Отзывы: