![Rapid 110 HL 50/2 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/rapid/110-hl-50-2/110-hl-50-2_operation-manual_3685886004.webp)
2.2.5
Check the hose, tubes and couplings daily. Replace worn or damaged
parts immediately. Do not repair high pressure couplings; you must
replace the entire hose.
2.3 Moving parts hazard
Moving parts, such as the air motor piston, can pinch or amputate your fingers.
2.3.1
Keep clear of all moving parts when you start or operate the pump.
2.3.2
Before you service this equipment, follow the pressure relief procedure
to prevent the equipment from starting unexpectedly.
2.3.3
Before operating the pumps, moving parts should not be exposed
outside.
2.4 Fire and explosion hazard
Improper grounding, poor ventilation, open flames or sparks can cause a hazardous
condition and result in a fire or explosion and serious injury.
2.4.1
Ground the equipment and the object being dispensed to.
2.4.2
Effective lubricate to the moving parts.
2.4.3
If there is any static sparking or you feel an electric shock while using this
equipment, stop dispensing immediately. Do not use the equipment until
you identify and correct or the fluid being dispensed.
2.4.4
Provide fresh air ventilation to avoid the buildup of flamable fumes from
solvents or the fluid being dispensed.
2.4.5
Keep the dispensing area free of debris, includiong solvent, rags and
gasoline.
2.4.6
Do not smoke in the dispensing area.
3. Technical data
4. Description
The pumps 110 HL 50/2 and 110 HL 200/2 are designed to be used in pumping greases
5. Assembling / Installation
5.1 Grounding
5.1.1
Warning: before operating the pump, cvheck the grounding of whole
system. And avoid occurring of fire and explosion.
5.1.2
To reduce the risk oft static sparking, effectively ground all of this
equipment.
Model
110 HL 50/2
110 HL 200/2
Art.No.
60 010
60 011
Grease oulet pressure max.
Ratio
Output
Outlet
Suction tube
740 mm
940 mm
Air inlet
Air inlet max.
Air motor diameter
76 mm
600 bar
50:1
1800 g/min
1/4" BSP
5-10 bar
12 bar
Model
110 HL 50/2
110 HL 200/2
60 010
60 011
600 bar
Ratio
50:1
Output
1800 g/min
1/4" BSP
740 mm
940 mm
5-10 bar
12 bar
76 mm
Art.No.
Grease oulet pressure max.
Outlet
Suction tube
Air inlet
Air inlet max.
Air motor diameter
4
+49 (6158) 92980-0
Содержание 110 HL 50/2
Страница 6: ...6 Spare party and accessories 6 49 6158 92980 0...