background image

Compact Fire Fighters by Rapid Spray

Rapid Spray Fire Marshal Operators Handbook

2

WARNINGS

1. 

When mounting to any vehicle, ensure that you have read the Vehicle Owner’s Manual and 

that you comply with all the weight restrictions as specified by the vehicle manufacturer, 

as overloading can cause injury or death. Remember that one litre of water weighs one 

kilogram. Ensure equipment is secure during transport.

2. 

To ensure your own safety and that of your employees or colleagues (if applicable) you must 

comply with all relevant environmental, work place health and safety legislation and codes 

of practice. In particular be aware of Rural Fire Service guidelines for safety when fighting 

fires or backburning.

3. 

You must be in good mental health to operate this unit and not be under the influence of 

alcohol or any drugs that could impair your vision, physical strength, dexterity, judgment or 

other mental capacity.

4. 

Improper or careless use of this unit can cause serious injury. Minors should never be 

allowed to use this unit. This unit should not be used when bystanders or animals are in the 

area. This unit should never be used while children are in the area. 

5. 

Before using, check the electrical and fuel systems for damage and deterioration. Replace 

parts as necessary. Do not modify the equipment or use any attachments other than those 

specified by the manufacturer. 

6. 

Select and wear appropriate Personal Protective Equipment (PPE) in accordance with the 

label of the product you intend on using and your own safe work practices. 

7. 

Never leave the sprayer unattended without turning off the engine and relieving the line 

pressure.

8. 

All operators must be trained in safe use of this unit. 

9. 

Carry out maintenance as per the recommendations. Ensure that the unit is cool and 

securely stabilised on a level surface before commencing maintenance. 

Read all warnings below and obey any instruction stickers or warnings on the unit.

Failure to do so may result in serious bodily harm or death.

Содержание FIRE MARSHAL

Страница 1: ...FIREMARSHAL OPERATORS HANDBOOK Fire Fighting FIRE MARSHAL FIRE MARSHAL PLUS 250L 325L...

Страница 2: ...els 02 Warnings 03 Product Risk Assessment 04 Troubleshooting 05 Operation 05 Before Beginning Operation 05 Operation 06 Honda GX35 Engine 12 Kawashima Fire Pump 15 Cleaning Maintenance 17 Fire Marsha...

Страница 3: ...esign may change slightly from what is shown in this operators handbook WARNING Always obey vehicle and UTV ATV manufacturer instructions regarding loading and operation Please check weight restrictio...

Страница 4: ...ther mental capacity 4 Improper or careless use of this unit can cause serious injury Minors should never be allowed to use this unit This unit should not be used when bystanders or animals are in the...

Страница 5: ...niques don t lift on your own if 20kg bend knees and keep back straight Mix chemicals if applicable and fill fire fighting unit As above spray drift chemical spillage emission of vapours or flammabili...

Страница 6: ...drops fluctuates during standard operation 1 Restriction on suction line 2 Pump sucking air 3 Plugged filter 4 Damaged regulator 1 Inspect tank and suction lines and remove restriction 2 Tighten fitti...

Страница 7: ...upplied with the unit and ensure you follow all warnings and instructions contained within WARNING Motor is shipped without oil or fuel Before operation fill the motor with the correct oil and fuel as...

Страница 8: ...controls and learn how to stop the engine quickly in case of emergency Make sure the operator receives adequate instruction before operating the equipment Do not allow children to operate the engine K...

Страница 9: ...P DIPSTICK ENGINE CONTROLS CHOKE LEVER THROTTLE LEVER THROTTLE LEVER ENGINE SWITCH GX25 GX35 Applicable Types Centrifugal Clutch The centrifugal clutch automatically engages and transmits power when e...

Страница 10: ...e is level and the engine switch is in the OFF position Always check the following items before you start the engine Check the General Condition of the Engine 1 Look around and underneath the engine f...

Страница 11: ...ith engine startup shutdown or operation STARTING THE ENGINE Refer to the instructions provided with the equipment for throttle lever and engine switch 1 To start a cold engine move the choke lever 1...

Страница 12: ...ING THE ENGINE cont HONDA GX35 ENGINE CONT 4 Pull the start grip 4 lightly until you feel resistance then pull briskly in the direction of the arrow 5 Return the starter grip gently Notice Do not allo...

Страница 13: ...y 1 Turn the engine siwtch to OFF O B position 2 Move the choke lever to the OPEN position 3 Hold the throttle level 6 on the equipement in the MAX B position 4 Pull the starter grip 3 to 5 times Foll...

Страница 14: ...l medicinal liquids or caustic liquids such as used oil wine or polluted water To prevent fire hazards and to provide adequate ventilation keep the pump at least 1 meter 3 feet away from building wall...

Страница 15: ...l occur NOTE Discharge port angle can be changed to 3 different directions Adjust to your operating condition 4 Submerge the suction hose strainer in the water 5 Remove self suction plug and top up th...

Страница 16: ...ump will deliver the highest output volume Moving the throttle level toward the idle position will decrease the output volume of the pump OPERATION STOPPING ENGINE 1 Lower the throttle level fuly and...

Страница 17: ...engine Clean the air filter regularly particularly if working in a dusty environment Clean and adjust the spark plug as necessary Clean the cooling fan air intake opening and parts around the muffler...

Страница 18: ...ifications Daily Inspect the fuel line and filter check for leaks or contamination Weekly Clean air filter in accordance with engine manufacturers instructions see engine tab As needed Replace engine...

Страница 19: ...d the Honda Engine Operators Instruction Manual and Warranty Policy All repairs should be carried out by a licensed Honda dealer or maintenance shop or by any engine repair establishment or individual...

Страница 20: ...ription 1 AMPTC00200ATT 400BTT 1 200 400L Marshal Tank 2 3 4 ARLP250VSR 1 255mm Screw Lid 5 AMAXPM010BK 1 10L Rinse Tank only Marshal Plus units 6 7 CFNB20M 1 3 4 poly Drain Bun Seal 8 CFVTB20M 1 3 4...

Страница 21: ...25F1 Back end brass nut 6 CFBL25F2 Swivel end brass nut for hose reel 7 CFPPT25M220 25 220mm screw pipe piece poly 8 CHJCH01X100X30 Spring for FF hose reel 9 CUF14519MMX36N 36m length x 19mm fire hose...

Страница 22: ...ers in excess of the obligations of RAPID SPRAY expressly set forth herein NOTE All tank and spray systems must have their warranty activated by returning warranty card located at the end of this docu...

Страница 23: ...ons damaged by corrosive chemicals dirt and sand excessive heat moisture or other environmental impacts Warranty determination on these type of failures will be made by RAPID SPRAY only after inspecti...

Страница 24: ...Compact Fire Fighters by Rapid Spray Rapid Spray Fire Marshal Operators Handbook 22 This page has been left blank intentionally...

Страница 25: ...own Purchaser s Name Purchaser s Address Purchaser s Phone Number Email Address Disclaimer If you don t want us to keep you informed of new products please tick the following circle To help us help yo...

Страница 26: ...Compact Fire Fighters by Rapid Spray Rapid Spray Fire Marshal Operators Handbook 24 This page has been left blank intentionally...

Страница 27: ...JUN 2023 Rapid Spray Fire Marshal Operators Handbook 25 AYH013 NOTES...

Страница 28: ...Compact Fire Fighters by Rapid Spray Rapid Spray Fire Marshal Operators Handbook 26 NOTES...

Страница 29: ...JUN 2023 Rapid Spray Fire Marshal Operators Handbook 27 AYH013 NOTES...

Страница 30: ...s on 1800 011 000 or visit www rapidspray net 35 Enterprise Cres Singleton NSW 2330 PO BOX 3119 Singleton NSW 2330 Telephone 1800 011 000 Facsimile 02 6571 2951 Rapid Spray Liquid Management Systems A...

Отзывы: