background image

Operating instructions RS wash 

 D wash 

 P wash 

 SHERAprint wash

 

 3Dewash 

 

 

 

 

25 

 29 

Rapid Shape GmbH 

 DOCR000257 

 

3.

 

Disconnect the cleaning liquid container from the machine. 

4.

 

Remove the lid of the container and place it upside down (tubes 

facing upwards) on a flat surface. 

5.

 

Slide the bottom of the container to the RFID reader again. 

6.

 

Remove the rear (dirty) bottle and seal it with the lid kept in the 
container. Set the bottle aside. 

Then check if there are liquid residues on the bottom of the 

container. Clean these with a paper towel.

 

7.

 

Remove the front (clean) bottle and place it in the rear position 
of the container. Pay attention to the position markings on the 
bottle and container. The RFID tag on the bottle is read. 

8.

 

Open the new bottle of cleaning liquid. Place the bottle cap in 
the appropriate storage compartment of the container base. 

9.

 

Insert the new bottle in the front position of the container. Pay 
attention to the position markings on the bottle and container. 
The RFID tag on the bottle is read. 

10.

 

Put the lid back on. Insert the tubes into the bottle openings. 

When doing so, make sure that the container is not removed 

from the RFID reader.

 

11.

 

Reconnect the container to the coupling connection of the 
machine. The coupling must click in audibly. 

12.

 

Finish the wizard on the user interface. Return to the Home 
screen. 

13.

 

Dispose of the used cleaning liquid. 

 

 

 

 

 

NOTE! 
Wearing protective gloves protects the skin from contact 
with skin damaging materials. It is therefore essential to 
observe the information provided by the material 
manufacturer. 

 

 

 

 

 

Dispose of used cleaning liquid according to local waste 
disposal regulations. Please take note of the safety data 
sheets of the respective materials. 

 

8.2.2

 

Check and clean inner container 

 

Required accessories: 
Personnel: 

Paper towel, isopropanol, protective gloves 
Operator 

 

 

 

For checking and cleaning the inner container, please proceed as 
follows: 

1.

 

Put on protective gloves. 

2.

 

Open the drawer. 

3.

 

Check the inner container for wear. In case of severe signs of 
wear, the container can be changed. Separate installation 
instructions are enclosed with the spare part. 

 

4.

 

Check the inner container for soiling. Remove light soiling with a 
paper towel moistened with isopropanol. For persistent soiling, 
e.g. hard incrustations, the container can be replaced. Separate 

installation instructions are enclosed with the spare part. 

 

 

 

Содержание RS wash

Страница 1: ...SHERAprint wash 3Dewash Original operating instructions Rapid Shape GmbH Roemerstra e 21 71296 Heimsheim Germany Phone 49 0 7033 309 878 0 info rapidshape de www rapidshape de Revision 09 07 2019 Ver...

Страница 2: ...lations and general safety regulations apply to the area of application of the machine Redistribution and duplication of this document utilisation and communication of its contents are strictly prohib...

Страница 3: ...3 3 1 Safety during transport 13 3 2 Transporting the machine 13 3 3 Unpacking the Machine 13 3 4 Scope of delivery 14 3 5 Storing the machine 14 4 Installation 15 4 1 Safety during installation 15 4...

Страница 4: ...4 8 2 Overview of the cleaning maintenance work 24 8 2 1 Change cleaning bottles 24 8 2 2 Check and clean inner container 25 8 2 3 Check hose connections 26 8 2 4 Change the activated carbon filter 26...

Страница 5: ...symbol and signal word indicates a potentially dangerous situation which may lead to death or severe injury if not avoided CAUTION This combination of symbol and signal word indicates a potentially d...

Страница 6: ...manual Any use going beyond the intended use or otherwise is deemed to be improper The operator is exclusively liable for any resulting damage Use contrary to the intended use includes but is not limi...

Страница 7: ...ified electricians and in compliance with the relevant safety and VDE regulations Machines with damage to the power cord insulation or lack of earthing must be disconnect ed from the mains immediately...

Страница 8: ...id containers may only be lifted and tilted if the bottles contained in them had been removed first If necessary wear appropriate protective clothing Read the appropriate safety data sheets carefully...

Страница 9: ...cessary accessories and can recognise possible dangers independently and avoid hazards Operator obligations The operator is obligated to read these operating instructions fully before using the system...

Страница 10: ...ct people from negative impacts on their safety and health Personnel must wear personal protective equipment while working on and with the machine as referred to in the individual sections of this man...

Страница 11: ...DOCR000257 2 1 Machine Assembly Operating Elements Figure 1 Machine overview Lid USB Ethernet connection Coupling connection Power on off button RFID reader Quick coupling Drawer extension Cleaning li...

Страница 12: ...29 Figure 2 Overview cleaning liquid container Cleaning bottle 1 dirty Cleaning bottle 2 clean Container bottom Lid 2 2 Serial plate The serial plate is situated on the machine rear It shows the most...

Страница 13: ...d to the transport company and Rapid Shape Transport The machine can be transported by one person 1 Grasp the bottom of the transport packaging and transport it to the destination 2 Then unpack the ma...

Страница 14: ...y Cleaning liquid container Optionally additional accessories can be supplied For more information please contact Rapid Shape 3 5 Storing the machine Store the machine in a dry dust free and frost pro...

Страница 15: ...mediately Connect the mains plug to the nearest and correctly grounded socket of the machine Only operate the machine with the mains voltage specified for the machine Only operate the machine with the...

Страница 16: ...ound 4 Recommended Connect a network cable to the Ethernet port on your machine and to your network interface In this way software updates can be installed automatically 5 Then switch on the machine C...

Страница 17: ...he cleaning liquid needs to be changed and with a note on the user interface alerts you of a required bottle change Chapter 8 2 1 4 3 3 Connect to other machines The cleaning unit can be connected to...

Страница 18: ...Operating instructions RS wash D wash P wash SHERAprint wash 3Dewash Rapid Shape GmbH DOCR000257 18 29 In an emergency proceed as follows 1 Unplug the mains plug...

Страница 19: ...he material manufacturer 6 2 Switching on the machine To switch on the machine please proceed as follows 1 Prerequisite The machine has already been fully connected Chapter 4 3 2 Turn the machine on u...

Страница 20: ...we recommend inserting hollow models with the cavities downwards 6 4 Select operating mode start To start the cleaning process you can choose from the following three operating modes Operating mode J...

Страница 21: ...aning process 6 4 2 Operating Mode Material In the Material operating mode the cleaning process is performed based on the materials used To start the process please proceed as follows 1 The inner cont...

Страница 22: ...f the component observe the specifications of the material manufacturer when creating custom parameters Only by observing the instructions of the manufacturer can safe biocompatibility be ensured For...

Страница 23: ...down will appear The machine counts for 10 seconds until the switch off happens automatically 3 Wait for the machine to shut down completely 4 Switch off the machine using the power on off button 7 2...

Страница 24: ...s to avoid material damage to the machine 8 2 Overview of the cleaning maintenance work Interval What How Depending on use autom display Change cleaning bottles Chapter 8 2 1 1 month Check inner conta...

Страница 25: ...ing so make sure that the container is not removed from the RFID reader 11 Reconnect the container to the coupling connection of the machine The coupling must click in audibly 12 Finish the wizard on...

Страница 26: ...eparate installation instructions are enclosed with the spare parts 6 Close the lid and fasten it firmly to the housing with the fastening screws 7 Close the drawer 8 Check the hoses in the cleaning l...

Страница 27: ...ore the disassembly work begins Wear appropriate protective clothing Disassemble components properly Handle edged and pointed components carefully If necessary secure components so that they can not f...

Страница 28: ...ENVIRONMENTAL PROTECTION Incorrect disposal of electronic waste electronic components lubricants and other additives can be hazardous to the environment Therefore please dispose of machine components...

Страница 29: ...Ambient temperature C 15 to 40 Storage temperature C 15 to 70 Max humidity 70 All values are approximate 10 2 Dimensions and weights Width mm 230 Height mm 270 Depth mm 380 500 closed open Weight kg 8...