8.8
Post-process job
8.8.1
Clean/wash job
For the washing of your print job please proceed as follows:
1.
Wear protective gloves on your hands.
2.
Open the drawer of the RS wash cleaning unit.
3.
Position the collection basket with your components, or
alternatively individual components, in the inner container.
The components must never touch the rotors and cover each
other. The maximum filling level must not be exceeded.
4.
Close the drawer.
5.
Select the operating mode and start the cleaning process.
For more information, please refer to the separately
available operating instructions of the RS wash.
→
RS wash
8.8.2
Job post-exposure
For the post-exposure of your print job please proceed as follows:
1.
Wear protective gloves on your hands.
2.
Open the lid of the RS cure post-exposure unit.
3.
Place the cleaned components (
→
Chapter 8.8.1) in the
exposure chamber.
The components must not be stacked on top of each other and
should not cast shadows over each other. The maximum
component height must not be exceeded.
4.
Close the lid
5.
Select the operating mode and start the exposure/curing
process.
For more information, please refer to the separately
available operating instructions of the RS cure.
→
RS cure
8.9
Check the job
After the cleaning and curing process, check the component for the
desired result. If you notice that the print result deviates from the
desired result, please repeat the workflow or contact Customer service.