Operating instructions RS wash
│
D wash
│
P wash
│
SHERAprint wash
│
3Dewash
Rapid Shape GmbH
│
DOCR000257
16
│
29
4.2.2
Setting up the machine
For setting up the machine please proceed as follows:
1.
Prerequisite: The machine has already been unpacked.
→
Chapter 3.3
2.
Lift the machine and accessories to the desired installation
location and set them down.
3.
Remove all transport locks from the machine and the
accessories.
4.
Make sure that the four feet of the machine are completely
resting on the ground.
5.
Place the cleaning liquid container next to the machine.
4.3
Connecting
4.3.1
Power connection
To make the power connection, please proceed as follows:
1.
Prerequisite: The machine has already been set up.
→
Chapter 4.2.2
2.
Slide the cap of the power plug back until the stop and hold the
cap in this position. Then insert the plug into the power
connection of the machine.
Pay attention to the positioning of the plug. The flat plug side
must point inwards!
3.
Then, connect the power supply to the nearest outlet. Be careful
not to trip over cables lying around.
4.
Recommended: Connect a network cable to the Ethernet port on
your machine and to your network interface. In this way,
software updates can be installed automatically.
5.
Then switch on the machine.
→
Chapter 6.2
4.3.2
Cleaning liquid container
For equipping and connecting the cleaning liquid container please
proceed as follows:
1.
Prerequisite: The machine has already been switched on.
→
Chapter 6.2
2.
Call up the bottle change wizard on the user interface. Start the
wizard.
3.
Remove the lid of the cleaning liquid container and place it
upside down (tubes facing upwards) on a flat surface.
4.
Slide the bottom of the container to the RFID reader.
5.
Unscrew both bottles with cleaning liquid. Place the bottle caps
in the appropriate storage compartments of the container base.
6.
Insert a bottle in the rear position of the container. Pay attention
to the position markings on the bottle and container. The RFID
tag on the bottle is read.
7.
Insert the second bottle in the front position of the container.
Pay attention to the position markings on the bottle and
container. The RFID tag on the bottle is read.
8.
Put the lid back on. Insert the tubes into the bottle openings.
When doing so, make sure that the container is not removed
from the RFID reader.