background image

+49 (6155) 84 20-0

5

9. DAILY USE

Long time continuous running may cause motor overheating, the 
overheating protection system will cut the power automatically. The
motor can be restarted work again after cooling down by pressing the 
on/off button.

ATTENTION!
The suggested duty cycle is 2 hours. Do not exceed one 
hour when the environment temperature more than 30˚C
Please change the electric brush every 250-300hours

8.2 Start

Make sure all the joint parts without leakage. The tube outlet must 
be fixed well so to avoid pressure leaking.

8.3. Electrical Connections

• Terminal strip box complete of:
- ON/OFF switch;
- Speed regulating knob switch
- Speed regulating circuit board
• 5M Power cable

ATTENTION!
IT IS THE INSTALLER’S RESPONSIBILITY TO PREFORM THE 
ELECTRICAL CONNECTIONS WITH RESPECT FOR THE 
APPLICABLE REGULATIONS.

AC

Switch

M

Speed

regulating

circuit 

board

10. NOISE LEVEL

Under normal working conditions the noise emission from all models 
does not exceed the valve of 

80 db at a distance of 1 meter 

from

the electric pump.

Содержание WX 90

Страница 1: ...enstraße 2 64347 Griesheim Telefon 49 6155 8420 0 Telefax 49 6155 8420 50 www rapid group de info rapid group de Weiterentwicklung im Sinne des Fortschrittes behalten wir uns vor Technical Modifications are subject to change Details techniques subject à modification sans avis préalable n WX 90 28 400 i OPERATINGINSTRUCTIONS ...

Страница 2: ...der irregularity and obviously dangerous status 2 5 The pump should install the detection alarm system when it was installed at the location where may cause the failure or personal injury 3 Using 3 1 Wear protective clothing goggles and in accordance with the safe production routine when operate the corrosive and hazardous substance 3 2 It is prohibited to use plastic or aluminum alloy pump pipe a...

Страница 3: ...0 20000 Rated Speed RPM Load Speed RPM PUMP MODEL ELECTRICAL POWER 3 7 Install the filters in the pump tube bottom when transport the liquids with impurity or solids To avoid the blocking please check and clean it regularly 3 8 Make sure the motor under close status before power on Never leave the pump unattended and never operate the motors without pump 3 9 Do not touch the tube bottom after swit...

Страница 4: ...mpletely 8 1 4 The motor and pump tube position could be adjusted by 360 Put the pump tube adjusted to the suitable position and lock the nut to finish the installation It is recommended that the pump exports away from the motor power cable 7 MOVING AND TRANSPORT The pump tube and motor adopt the carton box packing There is enough protection packing material inside However never knock on heavy loa...

Страница 5: ...ours 8 2 Start Make sure all the joint parts without leakage The tube outlet must be fixed well so to avoid pressure leaking 8 3 Electrical Connections Terminal strip box complete of ON OFF switch Speed regulating knob switch Speed regulating circuit board 5M Power cable ATTENTION IT IS THE INSTALLER S RESPONSIBILITY TO PREFORM THE ELECTRICAL CONNECTIONS WITH RESPECT FOR THE APPLICABLE REGULATIONS...

Страница 6: ...nsportation distance and height Too big liquids viscosity Check the type with supplier Liquids draining out Stop the pump The inlet block off Clean the inlet Liquids draining out Stop the pump Motor overload Check the liquids viscosity and pump lift Sliding bearing damage Change the sliding bearing and seal ring Coupling wear Change the coupling Seal ring wear Change the seal ring Circuit failure ...

Страница 7: ... 49 6155 84 20 0 7 ...

Страница 8: ...10 2014 49 6155 84 20 0 8 ...

Отзывы: