INSTALLATION
W A R N I N G
!
The user
MUST
read and be familiar with the
"Safety" section of this manual.
This hand held device is intended to be used
by trained personnel ONLY.
This manual
MUST
be read and thoroughly
understood by
ALL
personnel who operate,
clean, or maintain this equipment! Special care
should be taken to ensure that the warnings and
requirements for operating and servicing safely
are followed. The user should be aware of and
adhere to
ALL
local building and fire codes and
ordinances as well as NFPA, OSHA, and all
related country safety codes prior to installing,
operating, and/or servicing this equipment.
Personnel
MUST
be
GROUNDED
to prevent
a shock or spark during electrostatic operation.
Install and route the hoses so they are
NOT
exposed to temperatures in excess of 120
°
F
(49° C) and so that all hose bends are
NO LESS
than a 6-inch (15cm) radius. Failure to comply
with these parameters could cause equipment
malfunction that might create
HAZARDOUS
CONDITIONS!
W A R N I N G
!
Air Hose
Fluid Hose Recommendation
Ransburg recommends using a 80303-XX Fluid Hose
Assembly. This assembly is made to specifically fit the
fluid fitting size engineered into the applicator. This hose
is available from your authorized Ransburg distributor.
Available hose lengths are listed in "Accessories" in the
"Parts Identification" section of this manual.
Any user installed fluid hose used must be
rated for (100 psig) 6.9 bar working pressure
minimum.
Filters
1. Install an air filter assembly on the outlet of the
main air regulator. The filter should be 5 micron
with a maximum working pressure of at least 100
psig (6.9 bar). For Class 3 air quality, which is a 5
micron size and has a dew point of -4°F (-20°C),
the relative humidity (RH) of the air should be 5%.
2. Ransburg recommends that a fluid filter be installed
at the output of the fluid supply (pressure pot,
pump, circulating system, etc.). It is the end user's
responsibility to install the proper filter that meets
their system's requirements.
80345/80365
RANSFLEX SOLVENTBORNE
INSTALLATION
For proper safe function of the applicator, the
79727-XX Air Hose Assembly must be used (either
standard or quick disconnect style).
CAUTION
!
GENERAL INSTALLATION
REQUIREMENTS
1. Operator must make skin contact with handle of
applicator. If gloves are required use either gloves
with palm and finger cut out or conductive gloves.
See accessory pages for conductive gloves.
AH-15-01.2
19
Ranflex Applicators
-
INSTALLATION