- 20 -
Audio Signal Generator
Sinad Meter
6.1 ALIGNMENT PROCEDURES
This transceiver has been aligned at the factory and does not require any adjustments at installation.
The required test equipment listed are used for the test setup or alignment shown in Figure 6-1
Transmitter Test Setup and Figure 6-2 Receiver Test Setup. These test setups are used in part or total
during the following adjustments and refer to Page 59 for adjustment location.
6.1.1 PLL ALIGNMENT
ITEM U.U.T.
SETTING
ADJUST
POINT
MEASUREMENT
PLL 2
VCO Voltage
Set radio to 24.890 MHz, AM RX mode.
Frequency setting at 29.699 MHz.
Connect Multimeter to TP10.
L14
1.0 VDC
±
0.1
≤
4.5 VDC
PLL 1
VCO Voltage
Set radio to 24.890 MHz, AM RX mode.
Frequency setting at 29.699 MHz.
Connect Multimeter to TP11.
L13
1.0 VDC
±
0.1
≤
6.5 VDC
AM Frequency Set radio to AM RX mode.
Set Clarifier Control to 12 o’clock.
Connect Frequency Counter to TP16.
VC2
10.100 MHz
±
10 Hz
TX Frequency Set radio to AM TX mode.
Connect Frequency Counter to TP16.
VR8
10.100 MHz
±
10 Hz
VCO Output
Set radio to 28.000 MHz, AM RX mode.
Connect Oscilloscope to TP3.
L17 Maximum
Output
38.6950 MHz.
AM OSC
Set radio to AM TX mode. Mod off
Connect Frequency Counter to TP5.
L18
10.6950 MHz
±
10
Hz
USB OSC
Set radio to USB TX mode. Mod off.
Connect Frequency Counter to TP5.
L20
10.6975 MHz
±
10
Hz
LSB OSC
Set radio to LSB TX mode. Mod off.
Connect Frequency Counter to TP5.
L19
10.6925 MHz
±
10
Hz
6.1.2 TRANSMITTER ALIGNMENT
RCI-2995DX LEVELS ARE SHOWN IN [ ].
ITEM U.U.T.
SETTING
ADJUST
POINT
MEASUREMENT
TX Power
Set radio to 28.000 MHz, AM TX mode.
Modulation off.
Set radio to 28.000 MHz, USB TX mode.
AF signal 30mV, 1 KHz to microphone.
Connect Oscilloscope to TP17.
Set RF PWR Fully Clockwise.
Set Clarifier Control to 12 o’clock.
L18,L37,
L35,L34
Maximum Output.