30
Technical Data
This cooker is category II
2H3+
It is supplied set for either:-
a) group H natural gas or
b) LP gas.
A conversion kit from NG to LP gas is available.
INSTALLER: Please leave these instructions with the User.
DATA BADGE LOCATION:
Cooker back, serial number repeater badge below oven door opening.
Country of Destination: GB/IE
Gas
Electric
Natural Gas
20mbar
220 - 240V 50Hz
Butane
29mbar
Propane
37mbar
(See appliance data badge for test pressures)
Dimensions
Overall height minimum 893mm maximum 920mm
Overall width
1100mm See ‘Positioning of Cooker’
Overall depth
648mm
Space for fixing
See ‘Positioning of Cooker’
Minimum space above hotplate
650mm
Connections
Gas:
Electric
Rp
1
/
2
at rear right-hand side
220 - 240V 50Hz
Ratings
Natural Gas
L.P. Gas
Injector
Injector
Hotplate
Wok burner
3.5kW internal 80
3.5kW (246g/h)
internal 54
external 129
external 77
Large Burner
3.0kW 134
3.0kW (210g/h)
87
Medium Burners
1.7kW 109
1.7kW (119g/h)
68
Small Burner
1.0kW 75
1.0kW (70g/h)
51
Gas burner inputs based on Gross Calorific Value
Ovens Conventional Oven
Fan Oven
Oven
Browning Element
2.2kW
1.15kW
2.5kW
Grill
2.3kW
Warmer
160W
Maximum total electrical load at 230V 7.2kW*
*approximate total including oven lights, oven fan etc.