ELECTRICAL CONNECTION

Do not use an extension cord with this appliance.

Figure 2

Green/Yellow 
(earth)

Fuse (13A)

Blue (neutral)

Brown (live)

13A must be used and fitted with a 13A fuse “ASTA” ap-
proved to BS 1363.

If you replace the fuse, the cover must be refitted.  If the 
cover is lost, the plug must not be used until a replacement 
has been obtained from your supplier.  The color of the fuse 
cover is that of the insert in the base of the fuse recess or 
elsewhere on the plug.  Always state this color when order-
ing a replacement cover.

If your appliance has a moulded plug, you do NOT have to 
do the following assembly as shown in Figure 2.  Appliances 
with moulded plugs are ready to use as is.

IMPORTANT: The wires should be connected to the termi-
nals of the plug as follows:

• 

Earth to the terminal marked E or coloured Green or 
Green/Yellow.

• 

Neutral to the terminal marked N or coloured Blue.

• 

Live to the terminal marked L or coloured Brown.

When wiring the plug, ensure that all strands of wire are 
retained in each terminal.  The flexible main cable, plug and 
socket must not be exposed to flue products or be allowed 
to come in contact with a hot surface.  The cable must not 
be trapped or pulled taut when the appliance is pushed into 
position.

THIS UNIT SHOULD NOT, UNDER ANY CIRCUMSTANCES, 
BE UNEARTHED.

Electrical Connection

Use nominal 230 VAC, 50 Hz only.  

THIS APPLIANCE MUST BE EARTHED.  All external wiring 
must comply with the IEE Regulations for the Electrical Equip-
ment of Buildings.  Connections to the electrical supply can 
be made with either a plug and socket or be permanently 
wired via a double-pole switch.

The appliance is supplied with a 250VAC PVC (85 degrees 
C) core cable (0.5mm x 2 metres long).  Any replacement 
cable fitted must follow this specification.  The unit may be 
supplied with either a moulded or rewirable plug.  Should 
the plug not fit the socket at the installation site, it should be 
removed and replaced with the correct type of plug.

If a moulded plug is fitted which is not suitable, it must be 
removed and disposed of.  To avoid the risk of electrocu-
tion, a plug must not be left where a child may plug it into a 
supply socket.  It must not be used for any other appliance.  
A three pin plug to BS 1363 with a capacity of not less than 

4

Содержание RDZ60

Страница 1: ...enance Instructions Refrigerated Wine Storage Unit with Sentry System Refrigeration Monitor RWS38 RWS60DX RDZ60 RANGEMASTER REFRIGERATED WINE STORAGE UNIT Note This appliance is intended to be used exclusively for the storage of wine ...

Страница 2: ... 10 Features for model RWS60DX 11 Features for model RDZ60 12 Care and Cleaning 13 Cleaning condenser air flow 13 Cleaning the cabinet 13 Cleaning the interior 13 Cleaning the wine shelves 13 Cleaning the door gasket 13 Removing the wine shelves 13 Replacing the light tubes 14 Aligning the door 15 Energy Saving Tips 16 Troubleshooting Guide 17 Obtaining Service 18 Guarantee 18 NOTE This product co...

Страница 3: ...s name and address Installer s name and address The model number and serial number can be found on the data badge which is located inside the wine storage unit on the left side toward the top of the cavity Warranty Registration Help Prevent Tragedies Child entrapment and suffocation are not problems of the past Junked or abandoned refrigerators are still dangerous Even if they sit out for just a f...

Страница 4: ... can be installed around the unit as long as the grille and door access remain unob structed Leveling Legs Front Grille keep this area open Figure 1 Front Grille Do not obstruct the front grille The openings within the front grille provide air to flow into and exit from the refrigerator condenser For this reason it is important this area to not be obstructed and be kept clean Rangemaster does not ...

Страница 5: ...ble main cable plug and socket must not be exposed to flue products or be allowed to come in contact with a hot surface The cable must not be trapped or pulled taut when the appliance is pushed into position THIS UNIT SHOULD NOT UNDER ANY CIRCUMSTANCES BE UNEARTHED Electrical Connection Use nominal 230 VAC 50 Hz only THIS APPLIANCE MUST BE EARTHED All external wiring must comply with the IEE Regul...

Страница 6: ...een fitted with a Sentry System refrigeration monitor This monitor will let you know if your storage unit is not functioning properly for optimum wine storage and will alert you in the unlikely event there is an unstable condition Door Ajar Alarm If the door has been left open for over five 5 minutes the alarm will sound and the LED will flash green This will stop as soon as the door is closed Hig...

Страница 7: ...n 2 modes of operation for the internal lights functional default mode and showcase mode If you are in functional default mode the lights will turn on only if the door is open If you are in showcase mode the lights will be on whether or not the door is open When in showcase mode a light indicator is illuminated on the display Warning Alarms Your dual zone wine storage unit has been fitted with a S...

Страница 8: ... power cord Follow all local building codes when installing electrical and unit Product weight 54 kg 375mm 76 to 102mm 538mm 578mm 627mm 927mm 419mm Electrical voltage frequency 220 240 V 50Hz Energy efficiency class on a scale of A more efficient to G less efficient A Climate class SN 10 32 C N 16 32 C ST 18 38 C T 18 43 C T Temperature range from to 4 4 to 18 3 C Gross capacity 85 litres Net cap...

Страница 9: ...llow all local building codes when installing electrical and unit Product weight 75 kg 607mm 76 to 102mm 8 559mm 857 to 883mm 599mm 1179mm 648mm 651mm Electrical voltage frequency 220 240 V 50Hz Energy efficiency class on a scale of A more efficient to G less efficient B Climate class SN 10 32 C N 16 32 C ST 18 38 C T 18 43 C T Temperature range from to 4 4 to 18 3 C Gross capacity 170 litres Net ...

Страница 10: ...nd unit Product weight 62 kg ROUGH IN OPENING DIMENSIONS FOR RDZ60 DIMENSIONS FOR RDZ60 607mm 76 to 102mm 9 1168mm 861 to 886mm 547mm 588mm 636mm 651mm Electrical voltage frequency 220 240 V 50Hz Energy efficiency class on a scale of A more efficient to G less efficient B Climate class SN 10 32 C N 16 32 C ST 18 38 C T 18 43 C ST Temperature range from to 4 4 to 18 3 C Gross capacity 154 litres Ne...

Страница 11: ...s for aging or longer term storing in the rear Roll out Racks The six 6 roll out wine racks may be pulled out approxi mately 355 millimeters to facilitate adding or removing bottles Do NOT lean on or press down heavily on the wine shelves Doing so may damage the shelves and the wine bottles stored on them Pull the wine racks out gently and carefully to minimize unsettling your wine collection AVOI...

Страница 12: ...s for aging or longer term storing in the rear Roll out Racks The six 6 roll out wine racks may be pulled out approxi mately 355 millimeters to facilitate adding or removing bottles Do NOT lean on or press down heavily on the wine shelves Doing so may damage the shelves and the wine bottles stored on them Pull the wine racks out gently and carefully to minimize unsettling your wine collection AVOI...

Страница 13: ...Doing so may damage the shelves and the wine bottles stored on them Pull the wine racks out gently and carefully to minimize unsettling your wine collection AVOID pulling out more than one rack at any time to maintain stability Single Bottle Racks Since bottles are not stacked on top of each other you can easily view and access your inventory without disturbing other bottles see Figure 13 Vibratio...

Страница 14: ... cleaner or undiluted detergent Wine Shelves The racks may be cleaned with mild soap and water and a soft cloth Do NOT use any abrasive cleaners See below for instructions for removing the wine shelves Door Gasket The vinyl gasket may be cleaned with mild soap and water a bicarbonate of soda solution or a mild scouring powder Removing the Wine Shelves Model RDZ60 Dual Zone Wine Storage unit Unload...

Страница 15: ...e light enclosure channel Only a small part of the light tube should project below the ceiling of the wine storage unit DO NOT USE A HAMMER TO FIT THE LIGHT TUBE Place the light tube terminal cover plate back in the original position on the light enclosure s flange Reuse the original two screws to secure it in place Plug the wine storage unit into the electrical socket Check to see if the light tu...

Страница 16: ...e a 5 32 hex key for this procedure See Figure 15 below Figure 15 Hinge adapter screws loos en these to adjust door on the top and bottom of the door Remove the top hinge pin to re move the door Door must be parallel to top and sides of refrigerator 7 1mm minimum NOTE For door closer to work properly it is necessary to maintain a minimum space of 7 1mm between door and cabinet flange as shown This...

Страница 17: ...ts stored in your appliance 8 Allow hot items to reach room temperature before plac ing in product 9 Minimize door openings and duration of door openings 10 Use the warmest temperature control set point that meets your personal preference and provides the proper storage for your stored contents 11 For wine storage products a When serving temperatures are not required re turn the compartment s set ...

Страница 18: ...e 5 or 6 Plug in power cord Check house circuit Before You Call for Service If the unit appears to be malfunctioning read through this manual first If the problem persists check the troubleshoot ing guide below Locate the problem in the guide and refer to the cause and its remedy before calling for service The problem may be something very simple that can be solved without a service call Some reme...

Страница 19: ...available from your Rangemaster retailer and from Cowley Components Ltd Masons Road Stratford upon Avon Warwickshire CV37 9NR Tel 01789 269667 Fax 01789 415623 Guarantee Free 1st Year Parts Labour Guarantee Covers goods for the period of 12 months from the date of purchase subject of the below exclusions Terms and Conditions The appliance Has been correctly installed in accordance with current leg...

Страница 20: ...e buyer to corresponding changes improvements additions replacements or compensation for previously purchased products www rangemaster co uk 41011814 Rev F 6 3 13 Clarence Street Royal Leamington Spa Warwickshire CV31 2AD England Tel 44 0 1926 457400 Fax 44 0 1926 450526 E mail consumers rangemaster co uk ...

Отзывы: