WARNING – SERVICING TO BE CARRIED OUT ONLY BY AN AUTHORISED PERSON
Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.
26
Check in the
‘Technical Data’
section at the back of these
instructions that the cooker is convertible to the gas you
want to use.
n
n
This conversion must be performed by a competent
person, in accordance with these instructions and
with the local supply company requirements.
n
n
Failure to convert the appliance correctly could
invalidate any warranty or liability claims and lead
to prosecution.
n
n
The conversion instructions must be used in
conjunction with the rest of the appliance
instruction, in particular for information on
Standards, cooker positioning, connection, hose
suitability, etc.
n
n
When servicing or replacing gas-carrying
components, disconnect from the gas before
starting, and check that the appliance is gas sound
after completion.
n
n
DO NOT use reconditioned or unauthorised gas
controls.
n
n
Disconnect from the electricity supply before
conversion. Before electrical reconnection, check
that the appliance is electrically safe.
Injectors
Remove the burner caps and heads. Remove the old jets.
Fit the new jets: see
‘Technical Data’
section for correct jets.
Reassemble in the reverse order
(Fig. 8.1)
.
Tap Adjustment
Disconnect from the electricity supply.
Remove all control knobs. Open the oven door. Undo the 2
screws on the oven beak
(Fig. 8.2)
and remove. Remove the
3 fixing screws on the underside of the control. The control
panel should drop down slightly. It is held at each end by two
holes in the top edge
(Fig. 8.3)
that locate on the tags on the
inner panel.
Lift the control panel clear of the tags and pull the control
panel forward.
Take care not to damage or strain the wiring.
Bypass Screw Adjustment
Turn the bypass screw on each control clockwise to the stop
(Fig. 8.4)
. Refit the control panel.
A
B
C
ArtNo.311-0010 Injectors
A – Jet, B – Internal injector, C – External injector
ArtNo.0102-0011 - Screwing
the control valve bypass screw
ArtNo.061-0006 - 90SC - Removing the splitter
ArtNo.270-0032 - 90 Prof+ FX - Removing the control panel
8. Conversion to LP Gas
Fig. 8.1
Fig. 8.2
Fig. 8.3
Fig. 8.4
Содержание Professional+ FX 90 Dual Fuel
Страница 1: ...Professional FX 90 Dual Fuel Britain s No 1 Range Cooker USER GUIDE INSTALLATION INSTRUCTIONS...
Страница 4: ...iv...
Страница 36: ...31 Notes...
Страница 37: ......
Страница 38: ......