![Rangemaster Elise 100 Induction Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/rangemaster/elise-100-induction/elise-100-induction_users-manual-and-installation-instructions_3668097027.webp)
INSTALLATION
Check the appliance is electrically safe when you have finished.
23
ArtNo.130-0010 Electrical connections single-phase
L
N
230 V ac 50 Hz
10 mm² max
6 mm² max
L1
N
L3
L2
3N ac
230/400 V 50 Hz
6 mm² max
10 mm² max
Levelling the Cooker
It is recommended that you use a spirit level on a shelf in one
of the ovens to check for level.
Place the cooker in its intended position. Take care not to
twist it within the gap between the kitchen units as damage
may occur to the cooker or units.
The front feet and rear rollers can be adjusted to level the
cooker.
To adjust the height of the rear of the cooker use a 13 mm
spanner or socket wrench to turn the hexagonal adjusting
nuts at the front bottom corners of the cooker.
To set the front turn the feet bases to raise or lower.
Electrical Connection
The cooker must be installed by a qualified electrician, in
accordance with all relevant British Standards/Codes of
Practice (in particular BS 7671), or with the relevant national
and local regulations.
Current Operated Earth Leakage Breakers
The combined use of your cooker and other domestic
appliances may cause nuisance tripping, so we
recommend that the cooker is protected on an individual
RCD (Residual Current Device) or RCBO (Residual Current
Breaker with Overload).
IF IN DOUBT, PLEASE CONSULT A SUITABLY
QUALIFIED ELECTRICIAN.
n
n
WARNING: THE APPLIANCE MUST BE EARTHED.
Note:
The cooker must be connected to the correct electrical
supply as stated on the voltage label on the cooker, through
a suitable cooker control unit incorporating a double-pole
switch, having a contact separation of at least 3 mm in all
poles.
n
n
The cooker MUST NOT be connected to an ordinary
domestic power point.
Access to the mains terminal is gained by removing the
electrical terminal cover box on the back panel. Connect the
mains cable to the correct terminals for your electrical supply
type (
Fig.7-8
and
Fig.7-9
). Check that the connections are
correctly fitted and that the terminal screws are tight. Secure
the mains cable using the cable clamp.
Fig.7-8
Fig.7-9