26
INSTALLATION
Check the appliance is electrically safe and gas sound when you have finished.
L1
N
L3
L2
3N ac
230/400 V 50 Hz
6 mm² max
10 mm² max
6 mm² max
Electrical Connection
The cooker must be installed by a qualified electrician, in
accordance with all relevant British Standards/Codes of
Practice (in particular BS 7671), or with the relevant national
and local regulations.
Note:
The cooker must be connected to the correct electrical
supply as stated on the voltage label on the cooker, through
a suitable cooker control unit incorporating a double-pole
switch, having a contact separation of at least 3 mm in all
poles.
n
n
The cooker MUST NOT be connected to an ordinary
domestic power point.
Access to the mains terminal is gained by removing the
electrical terminal cover box on the back panel. Connect
the mains cable to the correct terminals for your electrical
supply type (
Fig. 8.11
and
Fig. 8.12
). Check that the links are
correctly fitted and that the terminal screws are tight. Secure
the mains cable using the cable clamp.
Final Checks
Hotplate Check
Check each burner in turn (refer to the
‘Hotplate Burners’
section at the front of the instructions).
Grill Check
Turn on the grill control and check that the grill heats up.
Oven Check
Set the clock as described earlier in the instructions, and then
turn on the ovens. Check that the oven fans start to turn and
that the ovens start to heat up.
Note:
The oven light bulb is not included in the guarantee.
Turn off the oven.
Final Fitting
Fitting the Plinth
Loosen the 3 screws along the front bottom edge of the
cooker. Hook the central keyhole over the central screw.
Twist and fit each end keyhole over their respective screws.
Tighten the fixing screws.
Remove the 3 screws for the plinth mounts along the front
bottom edge of the cooker
(Fig. 8.13)
. Fasten the plinth
using these screws (alternative colour screws can be found in
the loose parts pack).
Customer Care
Installer:
Please complete your details in this guide, inform
the user how to operate the cooker and hand over the
instructions.
Thank you.
ArtNo.130-0010 Electrical connections single-phase
L
N
230 V ac 50 Hz
10 mm² max
6 mm² max
Current Operated Earth Leakage Breakers
The combined use of your cooker and other domestic
appliances may cause nuisance tripping, so we recommend
that the cooker is protected on an individual RCD (Residual
Current Device) or RCBO (Residual Current Breaker with
Overload).
IF IN DOUBT, PLEASE CONSULT A SUITABLY QUALIFIED
ELECTRICIAN.
ArtNo.000-0006 - Securing the 110 plinth
Fig. 8.11
Fig. 8.12
Fig. 8.13