INSTALLATION
Check the appliance is electrically safe and gas sound when you have finished.
22
Dear Installer
Before you start your installation, please complete the details
below, so that, if your customer has a problem relating to
your installation, they will be able to contact you easily.
Safety Requirements and Regulations
n
n
This cooker must be installed in accordance with the
relevant instructions in this booklet, with the relevant
national and local regulations, and with the local gas and
electricity supply companies’ requirements.
n
n
This cooker is a Class 2 Subclass 1 appliance.
n
n
Before installation, make sure that the cooker is suitable
for your gas type and supply voltage. See the data badge.
n
n
The appliance must be installed in accordance with the
regulations in force and only in a well-ventilated space.
n
n
Read the instructions before installing or using this
appliance.
n
n
In your own interest and that of safety, it is law that all
gas appliances be installed by competent persons. Failure
to install the appliance correctly could invalidate any
warranty or liability claims and lead to prosecution.
In the UK the cooker must be installed in
accordance with:
•
All relevant British Standards / Codes of Practice, in
particular BS 5440 Part 2.
•
For Natural Gas – BS 6172 and BS 6891.
•
For LP Gas – BS 5482-1 (when the installation is
in a permanent dwelling), BS 5482-2 (when the
installation is in a caravan or other non-permanent
dwelling), or BS 5482-3 (when the installation is in a
boat).
•
The Gas Safety (Installation and Use) regulations.
•
The relevant Building / IEE regulations.
In the Republic of Ireland the cooker must be
installed in accordance with:
The installation must be carried out by a competent person
and installed in accordance with the current edition of IS 813
“Domestic Gas Installations”, the current Building Regulations
and reference should be made to the current ETCI rules for
electrical installation.
Provision of Ventilation
This appliance is not connected to a combustion products
evacuation device. Particular attention shall be given to the
relevant requirements regarding ventilation.
All rooms require a window that can be opened, or
equivalent, while some rooms require a permanent vent in
addition to the window.
In the UK
The room containing the cooker should have an air supply
in accordance with BS 5440 Part 2. All rooms require an
openable window or equivalent, while some rooms require
a permanent vent in addition to the openable window. The
cooker should not be installed in a bedsitting room with
volume less than 20 m³. If it is installed in a room of volume
less than 5 m³ an air vent of effective area 100 cm² is required;
if it is installed in a room of volume between 5 m³ and 10 m³,
an air vent of effective area 50 cm² is required; while if the
volume exceeds 11 m³, no air vent is required.
If there are other fuel burning appliances in the same room,
BS 5440 Part 2 should be consulted to determine the requisite
air vent requirements.
In the Republic of Ireland
Reference should be made to the current edition of IS 813,
which makes clear the conditions that must be met to
demonstrate that sufficient ventilation is available.
ArtNo.050-0011 - Installer information table
Installer’s Name
Appliance Serial Number
Installer’s Telephone Number
Installer’s Company
7. Installation
Содержание CLASSIC 110 GAS FSD
Страница 1: ...Classic 110 Gas Toledo 110 Gas Britain s No 1 Range Cooker USER GUIDE INSTALLATION INSTRUCTIONS...
Страница 4: ...iv...
Страница 38: ...31 Notes...