![Rangemaster CLASSIC 110 GAS FSD Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/rangemaster/classic-110-gas-fsd/classic-110-gas-fsd_user-manual_3659481026.webp)
26
Technical Data
This cooker is designed for use on
either
:-
NATURAL GAS
ES Cat I2H G20mbar at 20mbar
ES Cat 12E+, G20 at 20mbar/G25 at 25mbar
FR/ES Cat I3+ G30 at 28mbar, G31 at 37mbar
NB:
THE NATURAL GAS AND LP GAS VERSIONS OF THESE COOKERS ARE DIFFERENT MODELS AND
CANNOT
BE CONVERTED FROM ONE GAS FAMILY TO THE OTHER
INSTALLER: Please leave these instructions with the User.
DATA BADGE LOCATION : LOWER RIGHT HAND COOKER UPRIGHT (Remove storage drawer)
Country of Destination: GB/IE
Gas
Electric
Natural Gas
20/25mbar
220 - 240V 50Hz
Butane
28/30mbar
Propane
37mbar
(See appliance data badge for test pressures)
Dimensions
Overall height including optional
splashback
minimum 1060mm
maximum 1090mm
Overall height
minimum 893mm
maximum 920mm
Overall width
1100mm See ‘Positioning of Cooker’
Overall depth
648mm
Space for fixing
See ‘Positioning of Cooker’
Minimum space above hotplate
650mm
Connections
Gas:
Electric
Rp
1
/
2
at rear right-hand side
220 - 240V 50Hz
Ratings
Natural Gas
L.P. Gas
Hotplate
Injector
Injector
Wok burner
3.5kW
internal 80
3.5kW (246g/h)
internal 54
external 129
external 77
Large Burner
3.0kW
134
3.0kW (210g/h)
87
Medium Burners
1.7kW
109
1.7kW (119g/h)
68
Small Burner
1.0kW
75
1.0kW (70g/h)
51
Ovens
3.2kW
237
2.9kW (224g/h)
85
Grill
2.73kW
190
2.73kW (192g/h)
85
Gas burner inputs based on Gross Calorific Value
Warmer
160W
Содержание CLASSIC 110 GAS FSD
Страница 1: ...110 Gas FSD Users Guide Installation Service Instructions U106100 08 ...
Страница 25: ...25 Circuit Diagram ...
Страница 27: ...27 ...
Страница 28: ......