INSTALLATION
Check the ap pli ance is electrically safe and gas sound when you have fi nished.
Installation
Dear Installer
Before you start your installation, please complete the
details BELOW.
If your customer has a problem relating to your
installation they will be able to contact you easily.
Installer’s Name
Installer’s Company
Installer’s Telephone number
You must be aware of the following
safety requirements & regulations
Prior to installation, ensure that the local distribution
conditions (nature of the gas and gas pressure) and the
adjustment of the appliance are compatible.
This appliance shall be installed in accordance with the
regulations in force and only in a well ventilated space.
Read the instructions before installing or using this
appliance.
In the UK
the regulations and standards are as follows:-
In your own interest and that of safety, it is law that
all gas appliances be installed by competent persons.
CORGI registered installers undertake to work to safe and
satisfactory standards. Failure to install the appliance
correctly could invalidate any warranty or liability claims
and lead to prosecution.
This appliance should not be installed in a boat or
caravan.
The cooker must be installed in accordance with:-
All relevant British Standards / Codes of Practice, in
particular BS 5440 Part 2 2000
For Natural Gas - BS 6172 : 1990 and BS 6891 : 1998
For LP Gas - BS 5482-1:1994 (when the installation
is in a permanent dwelling). This appliance should
not be installed in a boat or caravan.
The Gas Safety (Installation and Use) regulations
1998.
The relevant Building / IEE regulations.
Provision of Ventilation
This appliance is not connected to a combustion products
evacuation device. Particular attention shall be given to
the relevant requirements regarding ventilation.
In the UK
The room containing the cooker should have an air supply
in accordance with BS 5440 Part 2 : 2000. All rooms require
an openable window or equivalent, while some rooms
require a permanent vent in addition to the openable
window. The cooker should not be installed in a bedsitting
room with volume less than 20m
3
. If it is installed in a
room of volume less than 5m
3
an air vent of eff ective area
100cm
2
is required; if it is installed in a room of volume
between 5m
3
and 10m
3
, an air vent of eff ective area 50cm
2
is required; while if the volume exceeds 11m
3
, no air vent
is required.
If there are other fuel burning appliances in the same
room, BS 5440 Part 2 : 2000 should be consulted to
determine the requisite air vent requirements.
Location of Cooker
The cooker may be installed in a kitchen/kitch en diner but
NOT in a room con tain ing a bath or shower.
NOTE:
An appliance for use on LPG shall not be installed
in a room or internal space below ground level.
e.g. in a basement.
Conversion
All models are supplied set for use on group H natural gas.
A conversion kit for LP gas is included with the appliance.
See the instructions that are supplied with the conversion
kit. After converting the appliance please attach the Gas
Conversion sticker over the appropriate area of the data
badge, this will identify the gas type the appliance is now
set for.
This appliance is designed for domestic cooking
only. Use for any other purpose could invalidate
any warranty or liability claim.