17
Assembly Instructions
CHECKING FOR LEAKS
$IWHUDOOFRQQHFWLRQVDUHPDGHFKHFNDOOFRQQHFWLRQVDQG¿WWLQJVRQWKH/3JDVWDQNYDOYHJDVKRVH
DQGUHJXODWRUIRUOHDNVZLWKDZDWHUDQGVRDSVROXWLRQ
7RSUHYHQW¿UHRUH[SORVLRQZKLOHWHVWLQJIRUDOHDN
$OZD\VSHUIRUPOHDNWHVWSULRUWROLJKWLQJWKHJULOO
'RQRWVPRNHZKLOHWHVWLQJIRUDOHDN
$OZD\VSHUIRUPOHDNWHVWVRXWGRRUVLQDZHOOYHQWLODWHGDUHD
'RQRWXVHDQ\VRXUFHRIÀDPHZKLOHWHVWLQJIRUOHDNV
• Do not use the grill until any and all leaks are corrected.
• If you are unable to correct a leak, disconnect the propane supply and call a gas appliance service
dealer.
PERFORM LEAK TEST
3UHSDUHOHDNWHVWVROXWLRQE\UDWLRRIOLTXLGGLVKVRDSDQGZDWHU
Total solution required is approximately 2 - 3 ounces (70 - 90 ml).
Put leak test solution in a spray bottle.
• Ensure all control knobs are in the
O
OFF position.
• Connect the gas hose to the gas supply.
• Open the LP gas tank valve.
6SUD\OHDNWHVWVROXWLRQRQDOOJDVFDUU\LQJFRQQHFWLRQVDQG¿WWLQJV3UHVHQFHRIEXEEOHVDWDUHDV
of applied test solution indicates a gas leak. If leaks are detected or you smell or hear gas, shut off the
gas supply valve immediately and repair or replace the defective part. Do not use the grill until
all leaks are corrected.
WARNING
ALL INSTRUCTIONS AND SAFEGUARDS ON THIS PAGE MUST BE FOLLOWED TO
PREVENT FIRE, DAMAGE AND/OR INJURY.
CAUTION
Only use the regulator and hose assembly provided!
If a replacement is necessary, please call
our customer service center. Do not use replacement parts that are not intended for this grill.