background image

Confidential 

Rane Service Manual 

 

Safety Instructions

 

 
Carefully read the applicable items of the operating instructions and these safety suggestions before using this 

product. Use extra care to follow the warnings written on the product itself and in the operating instructions. Keep 
the operating instructions and safety suggestions for reference in the future.  
 
1. 

Power Source.

 The product should only be connected to a power supply which is described either in the 

operating instructions or in markings on the product. 

 
2. 

Power Cord Protection.

 AC power supply cords should be placed such that no one is likely to step on the 

cords and such that nothing will be placed on or against them. 

 
3. 

Periods of Non-use.

 If the product is not used for any significant period of time, the product’s AC power supply 

cord should be unplugged from the AC outlet. 

 
4. 

Foreign Objects and Liquids.

 Take care not to allow liquids to spill or objects to fall into any openings of the 

product. 

 
5. 

Water or Moisture.

 The product should not be used near any water or in moisture. 

 
6. 

Heat.

 Do not place the product near heat sources such as stoves, heat registers, radiators or other heat 

producing equipment. 

 
7. 

Ventilation

. When installing the product, make sure that the product has adequate ventilation. Improperly 

ventilating the product may cause overheating, which may damage the product. 

 
8. 

Mounting.

 The product should only be used with a rack which the manufacturer recommends. The 

combination of the product and rack should be moved carefully. Quick movements, excessive force or uneven 
surfaces may overturn the combination which may damage the product and rack combination. 

 
9.

 Cleaning.

 The product should only be cleaned as the manufacturer recommends. 

 
10. 

Service.

 The user should only attempt the limited service or upkeep specifically described in the operating 

instructions for the user. For any other service required, the product should be taken to an authorized service 

center as described in the operating instructions. 

 
11. 

Damage to the Product

. Qualified service personnel should service the unit in certain situations including 

without limitation when: 

a.  Liquid has spilled or objects have fallen into the product, 
b.  The product is exposed to water or excessive moisture, 
c.  The AC power supply plug or cord is damaged, 
d.  The product shows an inappropriate change in performance or does not operate normally, or 
e.  The enclosure of the product has been damaged. 

 

Содержание Twelve MKII

Страница 1: ...d recipient you are hereby notified that any review dissemination distribution or duplication of this document is strictly prohibited If you are not authorized please contact Rane and destroy all copi...

Страница 2: ...Manual shall be solely your responsibility and Rane shall have no liability for any such repairs or service work All such service or repairs are performed at the sole risk of the person performing the...

Страница 3: ...E WITH ANY RANE DISTRIBUTOR OR AUTHORIZED REPAIR SERVICE CENTER IN THE PROVISION OF REPAIR SERVICES OR TO BE OR MAKE REPAIRS AS AN AUTHORIZED SERVICE CENTER ALL REPAIRS DONE BY ANY ENTITY OTHER THAN A...

Страница 4: ...heat registers radiators or other heat producing equipment 7 Ventilation When installing the product make sure that the product has adequate ventilation Improperly ventilating the product may cause o...

Страница 5: ...This button will toggle the Touch strip between Needle drop and hot cue modes LED State Dim off Bright when CUE MODE is active 8 Deck Focus Buttons DECK 1 Tact Switch w Red LED MIDI When this button...

Страница 6: ...TOP CHASIS SIDE AND BOTTOM BASE SIDE B DRAW THE TOP HOUSING FOLLOWING THE DIRECTION OF THE ARROW ABOUT DISTANCE 25 MM C TAKE OUT THE FRONT PANEL D LIFT THE ONE SIDE OF THE TOP HOUSING FOLLOWING THE D...

Страница 7: ...FFC AND 3 PCS LINE B REMOVE THE 23 PCS SCREWS C TAKE OUT THE CONTROL PCBA D REMOVE THE 11 PCS BUTTON FROM THE CONTROL PCBA E UNPLUG THE 1 PCS CONNETOR BEFORE REMOVAL OF THE P S PCBA F TAKE OUT THE 3...

Страница 8: ...L AND STEEL BALL AND SPRING C TAKE OUT THE LED PCBA D TAKE THE TOP CHASIS Fig 3 4 REMOVAL OF THE USB PCB ASSEMBLY AND OPEN FRAME TYPE Fig4 A UNPLUG THE ONE PCS CONNECTOR B REMOVE THE PCS SCREWS C TAKE...

Страница 9: ......

Страница 10: ......

Страница 11: ......

Страница 12: ...opper 3 15 0 1 MT122040801 Front panel painting 1 39 0 1 MT123002501 Top bracket painting 1 5 0 1 MT123031901 Bottom housing Cable trough pa 1 48 0 1 MT123032102 Bottom housing rame printing 1 38 2 MT...

Страница 13: ...SUPPLY CORD Long 2m CCEE 0A 0 1 SC0306RINI Screw M3X6 PPN 15 36 0 1 SC0308FABBI Screw 15 7 0 1 SC0308FIBI Screw M3X8 PFB 19 6 0 1 SC0308PBBI Screw M3X8 PBB Tapping 1 58 0 1 SC0308RBNI Screw M3X8 PRN T...

Страница 14: ...2 14 15 16 17 20 21 22 23 25 27 29 30 3 2 33 34 35 36 38 39 41 44 4 CS225K1603X5R CCAP SMD 2 2uF 16V 10 0603 X5R 2 C109 110 4 CS226K1006X5R CCAP SMD 22uF 10V 10 1206 X5R 1 C19 4 CS475K1605X5R CCAP SMD...

Страница 15: ...MOSFET DMP3099L P CHAN 30V 3 8A 2 Q1 5 4 TRDTC124ESM Trans ormer DTC 124EKA NPN 1 Q4 4 UHACM2012900 2P Chock 90 0 4A 2 0X1 2mm 1 L2 4 UHBLM18PG121SN1 Bead 120 25 2A 0603 6 L3 4 5 6 7 8 4 UHNR5040T4R7...

Страница 16: ...160g Horizonta DIP 11 SW1 2 3 4 5 6 7 8 9 10 11 3 TE591271001 Pin Header 180 Pitch 1 27mm Dual Row 5Pin 2 SMD 1 TE3 3 TWOTMSD8GC402 OTMSD8GC4 Program 1 JK1 4 OTMSD8GC4 Micro SD Card 8G Class 4 1 3 VR...

Страница 17: ...820J5003NPO CCAP SMD 82pF 50V 5 0603 NPO 1 C11 5 DIP6SMB47CA Diode TVS 47V 1 ZD1 5 DIS3J Diode S3J SMC 1 D1 5 ECS10716D Capacitor Electrolytic 100uF 16V 3 EC1 2 3 5 ECS22735GLE ECAP LOW ESR 220UF 35V...

Страница 18: ...n PCB Assembly 1 4 FCN2S1001601 FCN Dual Touch 180 Pitch 1 0mm 16P 1 FCN1 4 TE612000402 Connector 4Pin P 2 0mm 1 TE1 4 TE612000403 Connector 4P Socket 180 1 TE4 4 TE613960201 Connector 2P 180 2 TE2 3...

Страница 19: ...OC108 PIC10901 PIC10902 COC109 PIC11001 PIC11002 COC110 PIC11101 PIC11102 COC111 PIC11501 PIC11502 COC115 PID101 PID102 PID103 COD1 PID201 PID202 PID203 COD2 PID301 PID302 COD3 PID401 PID402 COD4 PID5...

Страница 20: ...PIC1602 COC16 PIC1701 PIC1702 COC17 PIC1801 PIC1802 COC18 PIC1901 PIC1902 COC19 PIC2001 PIC2002 COC20 PIC2101 PIC2102 COC21 PIC2201 PIC2202 COC22 PIC2301 PIC2302 COC23 PIC2401 PIC2402 COC24 PIC2501 P...

Страница 21: ...0501 PIC20502 COC205 PIC20601 PIC20602 COC206 PIC20701 PIC20702 COC207 PIC20801 PIC20802 COC208 PIC20901 PIC20902 COC209 PIC21001 PIC21002 COC210 PIC21101 PIC21102 COC211 PIC21201 PIC21202 COC212 PIC2...

Страница 22: ...FCN30005 PIFCN30006 PIFCN30007 PIFCN30008 PIFCN30009 PIFCN300010 PIFCN300011 PIFCN300012 PIFCN300013 PIFCN300014 PIFCN300015 PIFCN300016 COFCN300 PILD30001 PILD30002 COLD300 PILD30101 PILD30102 COLD30...

Страница 23: ......

Страница 24: ......

Страница 25: ......

Страница 26: ......

Страница 27: ...E4 TO CN2 PITCH_VR STOP_VR 3 3V STROBE KEYSCAN1 KEYSCAN2 KEY0 KEY1 KEY2 5V GPIO22 GPIO23 GPIO32 GPIO33 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 FCN1 TO FUN PCB 28V GPIO17 GPIO18 GPIO19 DGND GND 3 3V 3 3...

Страница 28: ......

Страница 29: ......

Страница 30: ......

Страница 31: ......

Отзывы: