Rane SRM 66 Скачать руководство пользователя страница 9

Manual-9

Figure 9. Manufacturing Facility System

Applications

One of the best ways to grasp the true versatility of the SRM 

66 is to observe one in action.

Figure 9 shows an installation using one SRM 66 to distrib-

ute sound throughout an entire manufacturing facility. Each 

Output can have different mix Inputs and Levels. For example, 

the offices may mix in a different page source than the shop 

floor. Also note that all three of the shop floor Outputs may have 

different mixes, Master Levels and Limiter thresholds.

The use of Output Groups allows a large variety of Remote / 

Output combinations. In this example both the offices and lobby 

have their own Remotes to control their own Output Levels, 

while the shop floor has two Remotes, either of which can con-

trol the level of all three Output Levels assigned to them.

The example shown in Figure 10 demonstrates a system using 

the SRM 66 for room 

combining. The fact 

that Group configura-

tions can be different 

in each Memory adds 

the versatility of link-

ing multiple Remotes 

together in one condi-

tion while separating 

them in another. In 

Memory 2, the Mas-

ter can control both 

Output Groups, while 

permitting individual 

control within each 

divided room.

Figure 10. Room Combining System

One thing to keep in mind in such a situation is the Group’s 

Level is 

not

 stored in each Memory. This allows you to change 

Memories without it resetting the Group’s Level each time. If 

a different Group Level is desired you can change the Group 

assignments. For example, in Figure 10 (Memory #2) you could 

assign Output 1, Output 2 and Remote 1 to Group 3. When 

you changed from Memory #1 to Memory #2 the Group’s Level 

would change to the last value set for that Group. If your ap-

plication requires no change in Level between Memories, simply 

keep the Group Level assignments (to Outputs and Remotes) 

intact between Memories.

Other applications for the SRM 66 are time of day clocks 

with contact closure outputs which adjust the level and/or distri-

bution of audio for scheduled events. Or connect the SRM 66’s 

MRP through a relay 

to the power switches 

on noisy machinery to 

increase and decrease 

background or paging 

audio during use in 

manufacturing facili-

ties.

Содержание SRM 66

Страница 1: ...through 6 the assign Outputs to Output Group page the assign Remote to Group page the assign Group to Master Remote page the Group Levels page and the Memory page WEAR PARTS This product contains no wear parts The bottom buttons marked and are the left right cursor buttons These select the underlined parameter to edit Rotating the DATA knob changes the parameter setting Let s start by navigating t...

Страница 2: ... left or right When any parameter is selected the DATA wheel adjusts that parameter When the EXE button is held and MIN is pressed the selected parameter jumps to its lowest value see EXE Execute button Several commands are implemented with this button Holding down EXE while pressing MAX alters the selected parameter to its highest nominal value Holding down EXE while pressing MIN alters the selec...

Страница 3: ...Configuration feature found in SRM Exchange software See DSC 1 SRM Exchange software on page Manual 9 REMOTE INTERFACE PORT RIP This Port supports up to seven optional SR 1L Smart digital Remote controls see page Manual 6 Each Remote may be assigned to adjust the Level of any one of the six SRM 66 Output Groups or the Master Group OUTPUT GAIN switches These assist setting the optimal gain structure...

Страница 4: ...in the grounding inside a unit s or between units somewhere Your mission is to discover how your particular system wants to be grounded Try these things 1 Try combinations of lifting grounds on units that are supplied with ground lift switches or links Other than in your own home it is illegal and unsafe to use 2 prong to 3 prong AC line cord cheaters even though this is a common short term remedy...

Страница 5: ...emory page an asterisk appears in this field whenever the current working Memory does not match the last recalled Memory Programming the SRM 66 Programming each SRM 66 Output requires only one edit page as in Figure 1 Note that unique Input mix levels are pos sible for each Output All adjustments are in 1 dB steps The following parameters define each Output IN1 Input one mix Level 6 dB to 25 dB Off I...

Страница 6: ... 1 SRM Exchange Software When using the SRM 66 s Master Slave feature RIP must be set to SLAVE A single SR 1L can control Output Groups across multiple SRM 66 s For information on Master Slave functional ity see the RaneNote Advanced Applications of the Ingenious SRM 66 and SR 1L SR 1L Remotes The SRM 66 provides a Remote Interface Port which sup ports up to seven optional SR 1L Smart Remote contr...

Страница 7: ...e solution to recalling four Memories from a remote location The MRS 4 mounts in a standard U S electrical box with a minimum depth of 2 25 5 5 cm If connected to the MRP in Normal mode this remote allows up to 4 Memories to be recalled See the Nor mal section of Table 1 on the following page See the MRS 4 Data Sheet for hookup and operating instructions RCP 3 and RCP 4 Room Combining Panels The o...

Страница 8: ...short list of suitable cable types CONSOLIDATED ELECTRONIC WIRE AND CABLE Plenum cable Unshielded remote control signal cable CAT 9896 Shielded remote control signal cable CAT 9877 or 9852 WEICO WIRE CABLE INC Communication and control cable Multiconductor unshielded CAT 7606 ALPHA Communication and control cable Multiconductor unshielded CAT 1175C BELDEN Unshielded remote control signal cable CAT...

Страница 9: ...link ing multiple Remotes together in one condi tion while separating them in another In Memory 2 the Mas ter can control both Output Groups while permitting individual control within each divided room Figure 10 Room Combining System One thing to keep in mind in such a situation is the Group s Level is not stored in each Memory This allows you to change Memories without it resetting the Group s Le...

Страница 10: ...ion ally required in applications with multiple contact closure sen sors This feature is provided via the completely programmable SRM 66 Memory Recall Port using SRM Exchange software see the DSC 1 Data Sheet To externally control an SRM 66 from an AMX or Crestron first read Using a Control System with an SRM 66 There are 3 modes of operation for the SRM 66 RIP DSC SLAVE To externally control the S...

Отзывы: