QUICK START

This section is intended to help you make the physical con-

nections and software manipulations necessary to get up and 

running with your sleek new RPM 2m. If you don’t read the en-

tire Hardware Manual, at least read this section. It is also recom-

mended that you read the Quick Start section of the Drag Net 

Software Manual. If the Drag Net software is not yet installed 

on your computer, please install it now. 

To be safe, leave the audio connections until last. Begin by 

connecting the IEC power cord. Observe that the 

POWER 

LED 

on the front panel illuminates. After a few seconds, the 

STATUS 

LED should turn from red to yellow to green, and the 

PRESET 

display should have a number in it (00, if it’s the first time you’ve 

powered the device). If the 

POWER 

comes on, but the 

STATUS 

LED does not turn green, contact the factory.

Connect one end of the Ethernet crossover cable (supplied 

with the unit) to the 

10Base-T

 jack on the rear panel. Connect 

the other end of the cable to an Ethernet port on your computer. 

The 

LINK 

LED on the rear panel should be lit. If it is not, verify 

that you are indeed using a crossover cable, not a standard Ether-

net cable. Only use a standard Ethernet cable if you are connect-

ing the RPM 2m and a computer indirectly using an Ethernet 

switch. Launch the 

Drag Net

 application and follow the steps 

to create a new project and new RPM 2m device configuration. 

Double-click the 

Configure Hardware IP

 shortcut and follow 

the instructions to set the unit’s IP address to be compatible with 

your computer’s Network settings. 

Tip: If you aren't sure what IP 

to use, try the address 192.168.69.69 and subnet 255.255.255.0. 

This finds the default factory address 192.168.69.22 on the RPM 

unit,without manually setting it.

PROGRAMMABLE

MULTIPROCESSOR

INPUT

OUTPUT

1

2

1

2

AES3

A

B

VIP

POWER

ETHERNET STATUS

RPM 2m

PRESET

Now click on the 

Poll 

button in the toolbar to find for all 

devices. A device name and IP address should appear under the 

Live 

folder in the 

Project 

window. If a device does not appear, 

consult Drag Net’s online 

Help 

for instructions on configuring 

and verifying your computer’s Network settings.

The audio path within the RPM 2m is displayed in Drag 

Net’s 

Device Configuration

 window as a collection of blocks 

wired together to form a 

Processing Map

. These maps are cre-

ated offline as 

Storage 

configurations, which are then trans-

ferred to a 

Live 

unit. Drag blocks from the 

Palette 

onto the 

Processing Map

 and wire them together to create the audio 

path. Save this file frequently using the 

File > Save 

command. 

Transfer the selected 

Storage 

configuration to a 

Live 

unit using 

the 

Transfer Config

 button in the 

Project 

window. A new, 

minty green 

Device Configuration

 window opens once the 

transfer is complete, indicating you are now online with a 

Live 

device. Double-click a processing block to display and adjust its 

Properties 

(parameters) in real time on a 

Live 

device — there 

is no need to go offline to make parameter changes.

Once you have a useful configuration in the unit, connect 

balanced audio 

INPUTS 

to the Euroblock 

or

 XLR connectors, 

and connect either or both jack types (if you wish) to the 

OUT-

PUTS. 

Then turn on the amplifier. As a precautionary measure, 

all outputs are muted during 

and 

after a configuration transfer. 

Unmute each output individually, or use the handy 

Mute Out-

puts

 button in the toolbar. Once all outputs are unmuted, audio 

passes through the unit along the connections 

you 

defined.

Содержание RPM 2m

Страница 1: ...u aren t sure what IP to use try the address 192 168 69 69 and subnet 255 255 255 0 This finds the default factory address 192 168 69 22 on the RPM unit without manually setting it PROGRAMMABLE MULTIPROCESSOR INPUT OUTPUT 1 2 1 2 AES3 A B VIP POWER ETHERNET STATUS RPM 2m PRESET Now click on the Poll button in the toolbar to find for all devices A device name and IP address should appear under the Li...

Страница 2: ...ced analog audio INPUTS 1 and 2 on Euroblock and XLR connectors See Audio Connections on the following page Balanced analog audio OUTPUTS 1 and 2 on Euroblock and XLR connectors AES3 digital audio OUTPUT uses a fixed 48 kHz sample rate and 24 bit word length See Audio Connections e VERSATILE INPUT PORT provides 8 logic or voltage inputs for remote level control and Preset recall on a Euroblock f LA...

Страница 3: ...pre at the 15 dB setting and set digital trim to 3 dB When you re hooking up a consumer CD player with a single ended output for example and you really need an extra 6 dB of gain for a total of 18 dB of front end gain set the mic pre to 18 dB WARNING when using the mic pre as a low noise line stage make sure the phantom power is turned off Analog Output Stage Analog output is real easy There is a D...

Страница 4: ... appropriate VIP pin with the Auto Mixer Ducker s Input in Drag Net s Remote Map Again see our Drag Net Applications for examples VIP Level control Connect a 0 5 VDC source to a VIP pin from an AMX or Crestron card to adjust any or all Level blocks placed in the Processing Map Use Groups in Drag Net s Remote Map to link one or more Level blocks so they track each other when using a VIP pin Be cert...