background image

Professional Audio Products Data Sheet

MPE 14 & MPE 28

PROGRAMMABLE EQUALIZERS

Parameter

Specification

Limit

Units

Conditions/Comments

Equalizer: Channels

(2) MPE 14; (1) MPE 28

..........Bands: MPE 14

(14) 2/3 Octave ISO Spacing

 40Hz to 16kHz

...................... MPE 28

(28) 1/3 Octave ISO Spacing

 31.5Hz to 16kHz

..........Type

Interpolating Constant-Q

..........Accuracy

3

%

Center Frequency

..........Range

+12/-15

1

dB

1 dB Step Size

..........Program Memories

128

Inputs: Type

Active Balanced/Unbalanced

..........Connectors

3-Pin & ¼" TRS

..........Impedance

15k

1%

..........Maximum Level

+20

1

dBu

Outputs: Type

Active Balanced/Unbalanced

..........Connectors

3-Pin & ¼" TRS

..........Impedance

200

1%

Balanced:100• Each Output

..........Maximum Level

+20

1

dBu

Overall Level Range

±12

2

dB

2 dB Step Size

RFI Filters

Yes

Memory Battery Life

3

50%

Yrs

Ray-O-Vac BR2325, or equal

MIDI Xmit/Rcv Buffer Size

5,000

Bytes

Bypass Switches

Yes

Each Channel Separate

Overload LED Thresholds

+16

1

dBu

Output or any Internal Level

Low Filter

15Hz, 18dB/Oct, Butterworth

3%

Hz

Frequency Response

15-45kHz

+0/-3

dB

THD+Noise

0.008

.001

%

+4dBu, 20-20kHz

IM Distortion (SMPTE)

0.009

.002

%

60Hz/7kHz, 4:1, +4dBu

Signal-to-Noise Ratio

MPE 14/MPE 28 re +20dBu

20kHz Noise BW, Balanced

108/104

2

dB

All Bands Centered, Unity Gain

103/98

2

dB

All Bands Centered, Max Gain

100/95

2

dB

All Bands Full Cut, Unity Gain

Channel Separation (MPE 14)

75

3

dB

40-20kHz

Power Supply Input

18-24VAC w/center-tap

10%

Vrms

Proposed AES RAP Standard

Power Supply Connector

6-pin mod plug

Wired per above

Safety Agency—Unit

..........Classification

Class 2 Equipment

National Electrical Safety Code

..........Design

Safety Extra-Low Voltage

VDE SELV

..........U.L. Listing

U.L. 813 Exempt

Class 2

..........C.S.A. Certification

C22.2 No. 1 Exempt

Class 2

..........CENELEC

IEC 65 Exempt

Harmonization Doc. HD 195.S4

—Remote Power Supply

Class 2 Equipment

..........U.L. Listed

E90493

UL 1012

..........230VAC Export Model

Meets requirements of IEC 950

TUV Approved

EMI/RFI Emission Levels

FCC Part 15 Compliance

Class A Digital Device

Satisfies VDE 0871

Class A Digital Device

Maximum Current

500

m A

RMS Current From Remote Supply

Unit: Construction

All Steel

..........Size

1.75"H x 19"W x 8.5"D (1U)

(4.4cm x 48.3cm x 21.6cm)

..........Weight

6 lb

(2.7 kg)

Shipping: Size

7" x 22" x 13"

(18cm x 56cm x 33cm)

..........Weight

11 lb

(5.0 kg)

Note: 0dBu=0.775Vrms