background image

Manual-2

Front Panel Description

1

 Channels 1 and 2 LEVEL controls

 set the overall desired gain through the unit. The range is from Off to +8 dB for balanced 

use, or from Off to +2 dB with unbalanced inputs. Unity gain is at approximately “6” (balanced) or “7” (unbalanced). Using the 

highest setting (without lighting the Overload 

(OL)

 indicator) yields the best signal-to-noise performance. The

 

OL indicator moni-

tors all critical points for excessive signal levels. It lights whenever these levels exceed 3 dB below clipping. Occasional flickering is 

normal; however, if it glows steadily, reduce the signal coming from the source, or turn down the LEVEL control.

2

 Channel BYPASS switches 

activates the “hard-wire” bypass function. When engaged (red 

BYPASS

 LED 

on

), all three pins of 

the input connectors directly connect to the same pins on the output connectors (hard-wired). Engaging this switch converts the 

ME60S into a relatively expensive patch cord, but one with pretty lights.

Filter RANGE switch:

 The gain range of the filter sliders is switchable (as a group) from ±6 dB for high resolution, to ±12 dB for 

maximum boost/cut capability.

4

 Channel LOW and HIGH CUT FILTER controls.

 LOW CUT sets the corner frequency (-3 dB point) for the low cut filter 

(high pass), adjustable from 10 Hz to 250 Hz. HIGH CUT sets the corner frequency (-3 dB point) for the high cut filter (low 

pass), adjustable from 3 kHz to 40 kHz.

5

 Filter level controls

 set the individual levels for each of the constant-Q filters. Their range is set by the RANGE switch 

3

. The 

grounded center-detent design ensures individual filters are off and bypassed when positioned to their centers.

6

 POWER switch & indicator

 glows yellow any time this switch is closed and power is, in fact, actually flowing into the ME60S.

10

40

15

150

30k

40k

10k

5k

250

3k

10

40

15

150

30k

40k

10k

5k

250

3k

0

6

3

3

6

0

6

3

3

6

±6

±6

10

0

2

4

8

6

10

0

2

4

8

6

ME60S

MICROGRAPHIC

EQUALIZER

CHANNEL 2

CHANNEL 1

HIGH

LOW

HIGH

LOW

CUT FILTERS

CUT FILTERS

400

31.5

25

40

63

50

100

80

160

125

250

200

315

12.5k

1k

630

500

800

1.6k

1.25k

2k

3.15k

2.5k

5k

4k

8k

6.3k

10k

20k

16k

400

31.5

25

40

63

50

100

80

160

125

250

200

315

12.5k

1k

630

500

800

1.6k

1.25k

2k

3.15k

2.5k

5k

4k

8k

6.3k

10k

20k

16k

OL

LEVEL

RANGE

BYPASS

OL

LEVEL

RANGE

BYPASS

±12

±12

0

 12

 6

 6

 12

0

 12

 6

 6

 12

POWER

1

2

3

4

6

5

Отзывы: