Rane MC 22 Скачать руководство пользователя страница 2

Manual-2

INPUT LEVEL control

This controls the overall level. Unity gain is

reached at “0”. With signal applied,  set this

control so the +4 dBu LED lights occasion-

ally. If the OL (overload) LED flashes, turn

the INPUT LEVEL control down.

THRESHOLD control

This control sets the point at which the Input

signal level causes the Compressor to

become active. See Figure 1 on page

Manual-4.

COMPRESSOR
ACTIVE/BYPASS switch

This switch compares compressed and non-

compressed signal. There is one for each

Channel. The INPUT LEVEL remains active

regardless of switch position.

adx

 LED

This illuminates whenever noise reduction is

active. This automatic downward expander

circuit acts like a gate to keep the system

quiet when no signal is present. When the

input level drops below -55 dBu, downward

expansion occurs at a ratio of 2:1. See

Figure 3 on page Manual-5.

RATIO control

Once the threshold is exceeded, the ratio of

input change to output change is determined

by this control. The compressor has no

effect when set at 1:1. But at 10:1, it takes

a 10 dB input signal increase above the

Threshold to produce a 1 dB increase in

Output Gain. See Figure 2 on page

Manual-4.

GAIN REDUCTION LEDs

These LEDs show the amount of average

signal reduction in dB. This aids in setting

the THRESHOLD and RATIO controls by

showing how much compression is occuring.

CHANNEL 2 OUTPUT

Same as Channel 1 Output.

CHANNEL 2 INPUT

Same as Channel 1 Input.

Содержание MC 22

Страница 1: ...pin or unterminated With the RATIO turned all the way down at 1 1 THRESHOLD turned all the way up to 20 dBu and the LEVEL controls in their center at 0 dB you have an expensive patch cord While sendi...

Страница 2: ...on is active This automatic downward expander circuit acts like a gate to keep the system quiet when no signal is present When the input level drops below 55 dBu downward expansion occurs at a ratio o...

Страница 3: ...hen either Channel s signal exceeds the set Threshold preserving stereo imaging CHANNEL 1 INPUT Choose between the balanced XLR or the balanced unbalanced TRS jacks but only use one Inserting a TS jac...

Страница 4: ...al increase depends on the RATIO setting An ordinary preamp set for unity gain or a straight wire has a ratio of 1 1 that is the output level tracks the input level perfectly A 2 dB change at the inpu...

Страница 5: ...and before the preamp If it s to function as a limiter to protect the speakers in the rig it would go after the preamp and before the power amp Another method is to insert the unit in the effect loop...

Страница 6: ...SION Let s run a stereo system with compression see Figure 1 on the next page For this example we use a Rane Mojo MX 22 2 Way Crossover and a Mojo MQ 302 Stereo Equalizer along with the MC 22 Stereo C...

Страница 7: ...Manual 7 Figure 1 Sound system with compression example Figure 2 Sound system with Driver protection...

Страница 8: ...email the factory download it from Rane s web site addresses on page Manual 12 or ask your dealer for a copy Rane s policy is to accommodate rather than dictate However this document contains suggesti...

Страница 9: ...Manual 9 VARIOUS XLR CABLE ASSEMBLIES...

Страница 10: ...term downward expander describes this application type ground Any electrical reference point for measuring voltage levels Usually a large conducting body such as the earth or an electric circuit conne...

Отзывы: