Rane MA 4 Скачать руководство пользователя страница 3

Data Sheet-3

MA 4

MULTICHANNEL AMPLIFIER

MA 4

100-240V

50/60 Hz 500 WATTS

MADE IN U.S.A.

RANE CORP.

Class 2 Wiring 

OUTPUTS

Active Low

Use Rane VR 2 or 20 k

Ω 

pot

HIGH-PASS

20Hz

40Hz

60Hz

80Hz

ON

4

+ – + – + – + –

+ – + – + – +

REMOTE LEVEL

4

4

FLAG

3

2

1

FAULT

Vr Vc

Vr Vc

Vr Vc

Vr Vc

+ – + – + – + –

+ – + – + – + –

3 2 1

MASTER

SLAVE

COMP

4 3 2 1

1 2 3 4

+ –

+ –

+ –

+ –

Vr Vc

Vr Vc

Vr Vc

Vr Vc

+ –

+ –

+ –

+ –

INPUTS

MODE

13

22

dBu

SENSITIVITY

4

3

13

22

dBu

SENSITIVITY

4

2

13

22

dBu

SENSITIVITY

4

1

13

22

dBu

SENSITIVITY

4

EXP ON

3

INT EXT

LOAD

2

INT EXT

LOAD

1

INT EXT

LOAD

4

INT EXT

LOAD

COMMERCIAL AUDIO

EQUIPMENT 24TJ

R

FOR CONTINUED GROUNDING 

PROTECTION DO NOT REMOVE

THIS SCREW. 

4

3

2

1

ON

4

3

2

1

ON

FOR CONTINUED GROUNDING 

PROTECTION DO NOT REMOVE

THIS SCREW. 

1

2

4

6

9

0q

5

7

8

3

1

 Universal voltage, power-factor corrected, switch mode power supply operates 85 to 260 VAC, 50 Hz or 60 Hz. The supply 

features under and over voltage protection, low inrush current and operates with up to 85% efficiency.

2

 INPUTS are balanced and accept up to +22 dBu via Euroblock connectors with strain-relief.

3

 SENSITIVITY controls allow continuous adjustment from +22 dBu to +4 dBu. Integrated limiter prevents clipping regardless of 

input level and sensitivity setting.

4

 REMOTE DC LEVEL control ports with Euroblock strain-relief connectors allow audio taper attenuation using optional VR 2 

remote (or use 10k to 100k Ω linear pot). Clickless muting may be implemented using a switch, connecting Vr to Vc.

5

 A soft knee COMPressor is provided with rms threshold relative to the limit threshold. ON/off setting affects all channels. This 

allows uncompressed operation with typical program material while reducing continuous sine-wave power. Ratio is 3:1; Attack is 

1.5 seconds; Decay is 3 dB per second; Soft knee span is 10 dB.

6

 Downward EXPander reduces noise in the absence of signal. ON/off setting effects all channels.

º   RMS Threshold: –70 dBFS; Ratio: 3:1; Attack: 50 ms; Gain reduction: 10dB/sec.

7

 Selectable 20 Hz, 40 Hz, 60 Hz or 80 Hz HIGH-PASS filters are provided. The setting affects all channels. Filters are 12 dB per 

octave, Butterworth alignment.

8

 Each channel is set for MASTER or SLAVE operation. Master channels write Fault Flag status. Slave channels read Fault Flag 

status.

•   The Master setting is used for remote fault reporting and/or automatic redundancy switching control.

•   The Slave setting is used for individual channel remote power sequencing or automatic redundancy switching.

9

 Individual FAULT FLAG ports are provided for each channel.

•   The Fault Flag uses high-side active drive and passive pull down. No fault = +5 volts. Fault = 0 volts.

•   Channels set to Master drive the Fault Flag high when no fault is present. Passive pull down pulls the Fault Flag low when a 

fault occurs or power is lost.

•   Slave channels read the status of the Fault Flag.

0

 Amplifier outputs are floating (not ground referenced) and are 

not

 bridgeable. Each channel delivers 100 watts into a 4 or 8Ω 

load. Average load impedance is estimated then used to determine the limiter threshold required to limit maximum power to 100 

watts and peak current to less than 7.5 amps. Impedance estimation requires a minimum of 3.3 watts and is averaged over 180 ms.

q

 External amplifier input is used for Internal, automatic redundancy switching.

w

 Comprehensive front panel metering is included for each channel:

•   Four segment, load sensitive headroom meter shows remaining headroom.

•   Limiter, Compressor and Expander indicators light when the associated dynamics control is active.

•   The Fault indicator lights when a fault is detected

•   The Load indicator if 

off

 when impedance is above 16Ω, 

on

 when impedance is between 2 and 16Ω and 

flashing

 when the 

impedance is below 2Ω.

•   The Ready indicator is 

off

 when the power switch is off, 

flashing

 when the power is switch is ON and the unit is in standby 

(Slave channel with high fault flag) and 

on

 when the channel is active.

dB Headroom

dB Headroom

dB Headroom

dB Headroom

3
6

12
24

Limit

1

Comp
Exp

Fault
Load
Ready

3
6

12
24

Limit

2

Comp
Exp

Fault
Load
Ready

3
6

12
24

Limit

3

Comp
Exp

Fault
Load
Ready

3
6

12
24

Limit

4

ON

Comp
Exp

Fault
Load
Ready

w

Содержание MA 4

Страница 1: ...power factor corrected supplies A long list of unique features ranging from constant load power to built in automatic redundancy switching to advanced dynamics control qualify the MA 4 for the most de...

Страница 2: ...0 40 60 80 Hz dipswitch select Load sensing 2 to 16 normal Green Load indicator on Low load detect Below 2 is low Green Load indicator flashing High load detect Above 16 is high Green Load indicator o...

Страница 3: ...Hz HIGH PASS filters are provided The setting affects all channels Filters are 12 dB per octave Butterworth alignment 8 Each channel is set for MASTER or SLAVE operation Master channels write Fault Fl...

Страница 4: ...L U A F D A O L Y D A E R P X E B d 3 B d 6 B d 2 1 B d 4 2 T I M I L P M O C T L U A F D A O L Y D A E R P X E 4 H C 3 H C 2 H C 1 H C P S D T S O H D N G Y T I V I T I S N E S 4 H C 3 H C 2 H C 1 H...

Страница 5: ...2 Z H 0 4 z H 0 6 z H 0 8 E D O M V 8 0 O T V 0 0 Y B D N A T S V 0 3 O T V 2 2 E T U M V 5 5 O T V 2 4 N O 1 M 2 M 3 M 4 M 1 M 2 M 3 M 4 M E S N E S Y L P P U S 5 2 R E T I M I L K A E P DETECT RMS...

Страница 6: ...selection of 20 40 60 or 80 Hz highpass 2nd order Butterworth filters Load sensitive limiter circuits shall prevent clipping and the associated loss of speech intelligibility A front panel LED shall i...

Страница 7: ...Rane VR 2 or 20 k pot HIGH PASS 20Hz 40Hz 60Hz 80Hz ON 4 REMOTE LEVEL 4 4 FLAG 3 2 1 FAULT Vr Vc Vr Vc Vr Vc Vr Vc 3 2 1 MASTER SLAVE COMP 4 3 2 1 1 2 3 4 Vr Vc Vr Vc Vr Vc Vr Vc INPUTS MODE 13 22 dBu...

Страница 8: ...P 4 3 2 1 1 2 3 4 Vr Vc Vr Vc Vr Vc Vr Vc INPUTS MODE 13 22 dBu SENSITIVITY 4 3 13 22 dBu SENSITIVITY 4 2 13 22 dBu SENSITIVITY 4 1 13 22 dBu SENSITIVITY 4 EXP ON 3 INT EXT LOAD 2 INT EXT LOAD 1 INT E...