Rane ECS Скачать руководство пользователя страница 10

HW Manual-10

Warning:

 Proper static discharge measures must be

followed when installing or configuring this card.

Figure 11. ECA 2 Installation with ECM 82e Phantom Power and network termination jumper locations

Figure 10. ECA 2 Block Diagram (detail from Data Sheet Block Diagram).

ECA 2 ECHO CANCELLER MODULE

DESCRIPTION

The ECA 2 is a continually adaptive Acoustic Echo

Canceller module for the ECM 82e Mixer using the Rane
QuickAdapt™ algorithm. The ECM 82eA Mixer is shipped
with the ECA 2 installed. The QuickAdapt algorithm allows a
single AEC to operate the entire system. This algorithm uses
the Rane exclusive Smart Last On™ feature to precondition
the AEC for a microphone gate change. This feature can be
disabled by setting a Mic Gate Depth to 0 dB on the ECM
82eA. If you want to maintain the QuickAdapt algorithm, but
you also want to keep a microphone opened, set the Mic Gate
Depth to -1 dB. Another QuickAdapt feature is to precondi-
tion the AEC for a microphone mute condition. This allows
standard Push-To-Talk microphones to be used. When using
the single AEC method, daisy-chain the Mixers by connecting
MIX OUT to MIX IN on the with the last connection before
the ECB 62e being the ECM 82eA. Only the ECM 82eA
requires its AEC Reference input to be connected.

Multiple ECM 82eA mixers can also be used in situations

where areas in the room are different. For example, table
microphones may only require soft suppression, while ceiling
microphones may require moderate or strong suppression.
This method of echo cancelling is called MZEC™ MultiZone
Echo Cancelling. When using multiple ECM 82eA mixers,
connect the MIX OUT of each mixer to its respective MIX #
input on the ECB 62e.

Since the Echo Canceller automatically adapts to the

room, training is not required.

To upgrade an ECM 82e to an ECM 82eA install the

ECA 2 by temporarily removing the top cover of the
ECM 82e and seating the module onto factory installed
standoffs on the motherboard. After installing the Echo
Canceller, disable Echo Canceller Bypass in RaneWare (see
the RaneWare Operators Manual).

AUX

ECHO CANCELLER

ECA 2 MODULE

TRANSMIT

IN

TRANSMIT

CTRL.

MIX

SIG/OL

DETECTOR

SIG

OL

E/C BYPASS

POST-GATE MIX

OUT

OUT

OPTIONAL

IN

OUT

RECEIVE

Σ

301

301

-10dBu

-14dBu

Σ

+4dB

OUTPUT

POST-GATE

PRE-GATE

Содержание ECS

Страница 1: ...guration recall Memory 1 and inputs will be routed to outputs To further simplify this process just recall Memory 16 and you are ready to adjust mic levels See RW Manual 21 for system setup procedures...

Страница 2: ...he table s ECM 82eA to soft suppression and the other ECM 82eA to moderate or strong suppression For these types of systems connect each MIX OUT of the ECM 82eA to its respective MIX input on the ECB...

Страница 3: ...Mic are used within ECS to identify the current audio state of the system i e where audio is present or absent The patented performance advantages and much of ECS s automatic functionality is derived...

Страница 4: ...Lights when audio is detected at any Port Output LEVEL VU meter Selectively displays all Port Inputs and Port 1 and 3 Outputs by using the PORT STEP see This is also an error display 3 by itself indic...

Страница 5: ...ol Device Address is set to an invalid address the COM LED continually flashes The Device Address can be changed without power cycling the unit See page HW Manual 13 RW 232 CONTROL INPUT This DB 9 fem...

Страница 6: ...o Bridge control is combined with the ECB 62e Right channel Audio Bridge Hardware Pad switches set Input attenuation on Ports 2 6 Software Programmable Level controls on all Inputs and Outputs combine...

Страница 7: ...controlled analog 8 channel Mic Line auto mixer An optional internal DSP Echo Canceller module is available either separately model ECA 2 or included model ECM 82eA Each Base supports up to 6 Mixers...

Страница 8: ...m s Master Mic When power is first applied the ECM 82e displays its DEVICE ADDRESS until it receives data from the ECB 62e Once data is received the ECM 82e lights LEDs 1 2 and 6 for about 1 second EX...

Страница 9: ...cho Canceller is used within this Mixer The average signal level at this input must be between 10 and 0 dBu ECS INTERFACE EXP OUT This RJ12 mod jack and supplied cable sends Expansion data connecting...

Страница 10: ...es to be used When using the single AEC method daisy chain the Mixers by connecting MIX OUT to MIX IN on the with the last connection before the ECB 62e being the ECM 82eA Only the ECM 82eA requires i...

Страница 11: ...connected to a known earth ground Refer to Figure 13 on the following page Figure 12 RS 3 daisychained power connections DATA To control the units from a computer use nine pin RS 232 cables 50 feet or...

Страница 12: ...Unbalanced source to balanced ECB 62e Input 1 conductor cable with shield Figure 13 ECS cable wiring Balanced mono source to a stereo ECB 62e with transformer type termination Balanced mono source to...

Страница 13: ...1011110 95 01011111 96 01100000 97 01100001 98 01100010 99 01100011 100 01100100 101 01100101 102 01100110 103 01100111 104 01101000 105 01101001 106 01101010 107 01101011 108 01101100 109 01101101 11...

Страница 14: ...more of the following 1 Re orient or relocate the receiving antenna 2 Increase the separation between the equipment and the receiver 3 Connect the equipment into an outlet on a circuit differ ent fro...

Отзывы: