background image

Manual-2

CP 31 - FRONT PANEL

 

PAGING TRIM

 control is used to adjust the Page Input preamplifier gain to match the microphone/source in use, 

not

 to set

the Page level at the Zone Output. The range is 30 dB to 60 dB.

 

PAGING MIC/LINE 

switch selects a 30 dB Input pad when set to LINE.

 

PAGING DETECT THRESHOLD

 sets the Page signal level required to gate a Page 

on

 and illuminate the ACTIVE

indicator (#5). The range is -

∞ 

(on) to +4 dBu.

 

PAGING OL (Overload) 

indicator lights when the Page Input preamplifier comes within 4 dB of clipping.

 

ACTIVE 

indicator lights when the Page signal level reaches the Paging Detect Threshold. 

Note that a Page is always Active

when the PAGING DETECT THRESHOLD is set to minimum (ccw).

 

PAGING ASSIGN 

switch selects whether the Page signal is sent to Zone A, Zone B, BOTH Zones, or OFF (no Zones).

 

PAGING LEVEL 

controls adjust the Paging Level in each of the two (A & B) Zones.

  

PROGRAM INPUT LEVEL

 controls allow independent level adjustment for the stereo or dual mono Program Input(s).

 

ZONE DUCKER DEPTH 

control

 

sets the Ducker Depth (the amount of Program attenuation during a Page) from 50 dB

(ccw) to 6 dB (cw). The Ducker 

release

 is ramped and not user-adjustable.

 

ZONE DUCKER OFF/ON

 switches independently turn each Ducker ON or OFF.

 

ZONE Output Meter 

displays PEAK signal levels at -10 dBu, +4 dBu, and +16 dBu.

 

ZONE LEVEL 

controls

 

adjust the overall Level for each Zone Output. This concentric pot allows independent adjustment

of Output Levels, or “stereo/master” level control by holding both the inner and outer knobs together.

 

PWR

 indicator lights when the CP 31 is connected to a powered RS 1 power supply.

Отзывы: