Rane AD 22D Скачать руководство пользователя страница 3

Manual-1

OPERATORS MANUAL

AD 22d

AUDIO DELAY

QUICK START

Quickly look around to make sure no one catches you read-

ing this. You’re aware this is the 

manual

 aren’t you? Wow! Most 

people only get about this far in a manual, but there are a few 

important things you should know about the AD 22d. So please 

keep reading. These few points are summarized in this Cliff Note 

version of the manual.

ADJUSTING SENSITIVITY.

 First apply a signal with 

nominal input level and adjust the SENSITIVITY controls so 

the red CLIP LEDs just light, then back off so the LEDs do not 

turn on, even with high signal peaks.

SETTING DELAY.

 Now that the input signal is calibrated, 

press the CHAN button until the CHAN LEDs indicate the 

channel you want to set. We cover the special case of adjusting 

both

 channels simultaneously later (both CHAN LEDs 

on

). 

Adjust the up/down buttons until the LED display shows the 

desired Delay. To adjust the Delay of the other channel press the 

CHAN button until the other channel’s LED is lit, and adjust 

the Delay as before.

STORING DELAY.

 Press the STORE button (the STORE 

LED stops flashing). This stores the current Delay values into 

each channel’s current Memory (A or B). The current Memory 

for each channel is indicated by the MEMORY LED lit when 

editing that channel. Both channel's current Delay values are 

stored with each press of the STORE button.

WEAR PARTS:

 This product contains no wear parts.

BYPASS

1

STORE RECALL CHAN

MILLISECONDS

MODE

MEMORY

2

A B

DISPLAY

2

1

1 ms

10 

μ

s

1

2

SIGNAL

CLIP

dBu

SIGNAL

SENSITIVITY

SENSITIVITY

CLIP

dBu

0

-16

+4

-20

-4

-12

-8

0

-16

+4

-20

-4

-12

-8

AD 22d

METERS

FEET

AUDIO DELAY

-10 dBV

-10 dBV

HOLD TO SET TEMP

COARSE

FINE

°C

°F

RECALLING DELAY. 

To recall a stored Memory, press 

RECALL. Each press of this button alternately recalls stored 

Memories (A then B then A…) for the selected channel only.

A quick way to recall Memories into both channels simulta-

neously, is to store both channel’s values into the same Memory. 

With 

both

 channels selected (both CHAN LEDs 

on

), press 

RECALL to restore 

both

 channel’s Memories at the same time.

SETTING TEMPERATURE.

 The AD 22d is factory set for 

22°C/71.6°F. To change this, press and hold DISPLAY MODE 

and press one of the up/down buttons. Use the 1ms/COARSE 

buttons for degrees Celsius or the 10µs/FINE buttons for degrees 

Fahrenheit. The LED display shows the temperature setting. 

Further pressing of the up/down buttons adjusts the temperature 

setting. This temperature is used, with constant 30% humidity, 

to calculate the speed of sound for converting delay times into 

distance.

Never connect anything except an approved Rane power supply 

to the red thing that looks like a telephone jack on the rear of the 

unit.

 This is an AC input and requires special attention if you do 

not have a power supply 

exactly

 like the one originally packed 

with your unit. See the full explanation of the power supply 

requirements elsewhere in this manual.

Note: Changing the Delay setting is nearly seamless, though a 

single audio click may be expected if an audio signal is present.

Содержание AD 22D

Страница 1: ...LL CHAN MILLISECONDS MODE MEMORY 2 A B DISPLAY 2 1 1 ms 10 μs 1 2 SIGNAL CLIP dBu SIGNAL SENSITIVITY SENSITIVITY CLIP dBu 0 16 4 20 4 12 8 0 16 4 20 4 12 8 AD 22d METERS FEET AUDIO DELAY 10 dBV 10 dBV HOLD TO SET TEMP COARSE FINE C F 260 45 ...

Страница 2: ...tilationopenings Ifrackmounting pleaseprovideadequate ventilation Equipment may be located directly above or below this unit but note that some equipment like large power amplifiers may cause an unacceptable amount of hum or may generate too much heat and degrade the performance of this equipment Protect the power cord and plug from damage caused by being walked on or pinched Protect the line cord...

Страница 3: ...STORE RECALL CHAN MILLISECONDS MODE MEMORY 2 A B DISPLAY 2 1 1 ms 10 μs 1 2 SIGNAL CLIP dBu SIGNAL SENSITIVITY SENSITIVITY CLIP dBu 0 16 4 20 4 12 8 0 16 4 20 4 12 8 AD 22d METERS FEET AUDIO DELAY 10 dBV 10 dBV HOLD TO SET TEMP COARSE FINE C F RECALLING DELAY To recall a stored Memory press RECALL Each press of this button alternately recalls stored Memories A then B then A for the selected channe...

Страница 4: ... current Delay values and the memory LEDs turn off if the two channel s current Memories are not the same 0 CHANNEL button Pressing this button advances the channel LEDs from CHAN 1 to CHAN 2 to BOTH The current Delay value of the selected channel is displayed in the LED display q DISPLAY MODE button LEDs This button changes the units of displayed Delay values from Milliseconds to Feet to Meters Th...

Страница 5: ...erated in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harm ful interference to radio communications However there is no guarantee that interference will not occur in a particular installa tion If this equipment does cause harmful interference to radio or television recept...

Страница 6: ...d the unit secured by replacing the knobs with the provided hole plugs AD 22d CONNECTION When connecting the AD 22d to other components in your system for the first time leave the power supply for last This gives you a chance to make mistakes and correct them before any damage is done to your fragile speakers headphones ears or brains The AD 22d passes audio while it is unpowered by virtue of its f...

Отзывы: