background image

of battery lifetime. It is thus recommended to either operate the 
Weather Station on the included AC/DC adapter or entirely deactivate 
the EL backlight (see above). 
 
 

11.2 Buzzer

 

The buzzer for the acoustic acknowledgement or alarm signals of the 
Weather Station can be switched ON or OFF by touching the BUZZER 
section. 
The switching condition ON or OFF is displayed directly in the 
BUZZER section as well as for about 30 seconds in the text section 
(Enabled/Disabled). 
 

11.3  

Alarm 

Upon touching the ALARM display key will – numbered and sorted 
according to the time of appearance – with 

٭

NEXT

٭

 all those set and 

activated alarms (outside the wake-up alarm) be displayed that have 
reached an alarm condition since their last deletion. 
Here for every respective alarm the time and date of appearance can 
be displayed by touching 

٭

ALARM

٭

 

12 PC 

Connection 

 
As an important feature exceeding the mere display on the Touch 
Screen the Weather Station allows the read-out of all measured 
and displayed time and weather data in form of complete history 
data sets on a PC. 

 

12.1 Data 

Storage 

For a comprehensive weather history the Base Station allows the 
internal storage of up to 1750 complete sets of weather data with time 
and date. These data sets are being stored in non-volatile ring buffer 
memory (EEPROM) and will not be lost even in case of an interruption 
of power supply (e. g. change of batteries). 
In case the memory capacity of the Weather Station is exhausted the 
oldest data sets stored will be overwritten by the new ones entered. 

 

 

48

Содержание WS-3500

Страница 1: ...TOUCH SCREEN WEATHER STATION MODEL WS 3500 Operation Manual 28...

Страница 2: ...ther Tendency 8 Air Pressure History 9 Operating and Setting of various Functions 9 1 Air Pressure 10 Additional Information to Function Outdoor Temperature 11 Operating and Setting of Functions Backl...

Страница 3: ...r Forecast Tendency Air Pressure and Air Pressure History Pressure Pressure History Indoor Temperature and Humidity Indoor Temp Humidity Outdoor Temperature and Humidity Outdoor Temp Humidity Furtherm...

Страница 4: ...ed by use of the switching areas ON or OFF UP or DOWN or by direct unit selection Advancing to any next respective menu step with NEXT leaving or terminating all respective modes with EXIT Every progr...

Страница 5: ...th methods allow the connection of Thermo Hygro Sensor and Base Station by cable or by 433 MHz radio signal 3 Putting into Operation At first it is to decide whether battery supply or mains supply AC...

Страница 6: ...connection of Thermo Hygro Sensor and Base Station can be used in case that the flexibility of 433 MHz radio transmission is not needed and data transmission absolutely free of any environmental inter...

Страница 7: ...ies to an authorized depot 3 2 2 AC DC Mains Adapter Firstly also insert two Type AA 1 5 V batteries into the battery compartment of the Thermo Hygro Sensor Immediately following this connect the AC D...

Страница 8: ...change and will automatically switch to the appropriate operating mode 3 3 System Start After inserting the batteries respectively connecting the AC DC adapter the LCD of the Weather Station will for...

Страница 9: ...transmission they can mostly be overcome by slightly moving the mounting locations Note Commonly the radio communication between receiver and transmitter in the open field reaches distances of about m...

Страница 10: ...in 8 steps from 0 to 7 Default 4 Time Zone Time Zones can be set in the range from 12 to 12 hours Default 0 hours for Central Europe DCF77 Radio Controlled Clock RCC ON OFF In setting OFF the clock i...

Страница 11: ...essure with regard to the local height above sea level Default 1013 0 hPa Weather Tendency Tendency Setting to a definite switching threshold 2 hPa to 4 hPa for a change in display of weather icons De...

Страница 12: ...er data form non volatile buffer memory EEPROM and reset of all set and or stored values to the factory settings set prior to shipment Acknowledge with CONFIRM Note It will take about 5 minutes for th...

Страница 13: ...g the displays MINMAX or ALARMS resp The continuance of the recalling process is essentially self explanatory With MINMAX the below shown menu step is activated which in return leads to the displays o...

Страница 14: ...ugh EXIT 6 Radio Controlled DCF77 Clock The Radio Controlled DCF77 Clock is normally controlled by the radio signal of the DCF77 time code transmitter and will thus set time and date automatically Und...

Страница 15: ...ing Date in DD MM YY format 24 hour time format or Date in MM DD YY format 12 hour time format Weekday Eng abbrev Date of Day Month 24 hour format or Weekday Month Date of Day 12 hour time format Seco...

Страница 16: ...the weather symbol in the TENDENCY section The text section last two lines on the LCD will show since when with time and date the weather condition corresponds to the presently displayed weather symbo...

Страница 17: ...ime resolution of the bar graph can be changed from fine 0 to 24 h to coarse 0 to 72 h and back by once touching the PRESSURE HISTORY section 9 Operating and Setting of the following Functions Air Pre...

Страница 18: ...hing the PRESSURE section Start with MAX in the menu section Note Display of the stored minimum values is from here possible through MIN analog to this example Display of stored value Proceed with MAX...

Страница 19: ...oceed with HI AL in the menu section Note Setting of the LO alarms is from here possible through LO AL analog to this example Setting of high alarm value with UP or DOWN Proceed with ON OFF Activate o...

Страница 20: ...acilities only pertain to the respective presently displayed value 11 Operating and Setting of Functions EL Backlight Light Buzzer and Alarm 11 1 EL Backlight Light For better readability of the LCD t...

Страница 21: ...at have reached an alarm condition since their last deletion Here for every respective alarm the time and date of appearance can be displayed by touching ALARM 12 PC Connection As an important feature...

Страница 22: ...ay of all present weather data with graphic symbols It further allows the display storage and printing of history data sets whose volume exceeding the maximum 1750 data sets of the Weather Station is...

Страница 23: ...3 Data Transmission by Cable Measuring Intervals Thermo Hygro Sensor 128 s 13 4 Indoor Data Measuring Intervals Indoor Data every 20 s Temperature Range 40 C to 59 9 C Display OFL outside this range R...

Страница 24: ...IEC LR6 Alkaline Batteries recommended Life Cycle approx 1 year or Power provided via Cable from the Base Station by using the AC DC Adapter 13 6 PC Connection Wiring COM Port Cable included Data Pro...

Страница 25: ...ual is highly recommended for the benefit of the user This product must however not be thrown in general rubbish collection points The manufacturer and supplier cannot accept any responsibility for an...

Отзывы: