Command reference
R&S
®
ZNL/ZNLE
862
User Manual 1178.5966.02 ─ 19
to select the adequate circuit model
before
executing this command.
●
CALCulate<Ch>:TRANsform:VNETworks:SENDed:EMBedding<PhyPt>:
PARameters:DATA
to load circuit data from the remote client.
Suffix:
<Ch>
.
Channel number
<PhyPt>
Physical port number
Parameters:
<TouchstoneFile>
String parameter to specify the name and directory of the loaded
Touchstone file.
If no path is specified the analyzer searches the current direc-
tory, which can be set and queried using
<Interchange>
FPORts | IPORts | SGATes
FPORts (or omitted)
Standard port sequence (network port 1 towards VNA, network
port 2 towards DUT)
IPORts | SGATes
Inverted port sequence (network port 2 towards VNA, network
port 1 towards DUT)
Example:
CALC:TRAN:VNET:SEND:EMB:TND FIMP
Select the "Serial .s2p" data circuit model.
MMEM:LOAD:VNET:SEND:EMB2 'C:\Users\Public
\Documents\Rohde-Schwarz\ZNL\VNET\Test.s2p'
Load a Touchstone file and assign it to the physical port no. 2.
Manual operation:
See
MMEMory:STORe:CABLe
<OutputDir>
Saves all predefined and user-defined Distance to Fault (DtF) cable types to the speci-
fied output directory.
Each DtF cable type is stored in a separate ASCII file
<cable name>.rsc
. The com-
mand silently overwrites files of the same name previously existing in the output direc-
tory.
Setting parameters:
<OutputDir>
Output Directory, must be created before the command is exe-
cuted
Example:
Usage:
Setting only
Options:
R&S
ZNL-K3
Manual operation:
See
VNA command reference