Command reference
R&S
®
ZNL/ZNLE
846
User Manual 1178.5966.02 ─ 19
Example:
MMEMory:STORe:CABLe 'C:\dtf-cables'
Saves all predefined and user-defined Distance to Fault (DtF)
cable types to the directory
C:\dtf-cables
.
Edit
*.rsc
files for user defined cable types, copy
*.rsc
files,
rename and edit them. Afterwards execute
MMEMory:LOAD:CABLe 'C:\dtf-cables'
to update existing and create new user-defined cable types.
Usage:
Setting only
Options:
R&S
ZNL-K3
Manual operation:
See
MMEMory:LOAD:CKIT
<CalKitFile>
Loads cal kit data from the specified cal kit file.
Setting parameters:
<CalKitFile>
String parameter to specify name and directory of the loaded cal
kit file. If no path is specified the analyzer searches the current
directory, to be queried with
?
Example:
MMEM:LOAD:CKIT 'C:\Users\Public\Documents
\Rohde-Schwarz\ZNL\Calibration\Kits\New_kit.calkit'
Load the previously created cal kit file
New_kit.calkit
from
the default cal kit directory.
... :MMEM:STOR:CKIT 'New_kit', 'C:
\Users\Public\Documents
\Rohde-Schwarz\ZNL\Calibration\Kits\New_kit.calkit'
Store the data for the user-defined cal kit
Newkit
and overwrite
the cal kit file
New_kit.calkit
.
Usage:
Setting only
Manual operation:
See
MMEMory:LOAD:CKIT:SDATa
<ConnectorType>, <CalKitName>, <StandardType>,
<StandardLabel>, <TouchstoneFile>[, <FirstPort>[, <SecondPort>]]
Loads cal kit data for a calibration standard from a specified Touchstone file. A restric-
tion on the port assignment may be defined in addition.
Use the newer command
MMEMory:LOAD:CKIT:SDATa:WLABel
to be able to distin-
guish cal kits by label.
Setting parameters:
<ConnectorType>
String parameter containing the name of the connector type.
<CalKitName>
String parameter containing the name of a calibration kit availa-
ble on the analyzer.
VNA command reference